OEM Carrier Draft Pressure Switch 0.18
Carrier

OEM Carrier Draft Pressure Switch 0.18" WC for PY3GNA042060NA

SKU: CARRIE-PY3GNA042060NA-PRESSURE_SWITCH-HK06WC061 Brand: Carrier
Guaranteed to fit PY3GNA042060NA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Draft Pressure Switch 0.18" WC for Model PY3GNA042060NA

This is the factory-specified OEM draft pressure switch (part number HK06WC061, superseded by HK06MB061) for the Carrier PY3GNA042060NA packaged gas/electric unit. The pressure switch monitors negative pressure produced by the draft inducer motor before each ignition cycle. If the inducer fails to generate sufficient airflow — or the switch itself fails — the furnace control board will lock out on a pressure fault, preventing any attempt at ignition and leaving you with no heat. Symptoms include a short-cycling inducer, a flashing diagnostic fault code, or a furnace that runs the inducer but never advances to ignition.

  • Specs: 0.18" Water Column (WC) set point | Normally open, closes on negative pressure | Honeywell/Resideo manufactured | Cross-references: IS20224-5236, 1938D2/B | Superseded OEM part: HK06MB061
  • OEM vs Generic: This OEM switch is factory-calibrated to the exact 0.18" WC trip point required by the Carrier PY3GNA042060NA control board. Generic switches frequently carry ±15% tolerance, which can cause nuisance lockouts or — worse — allow ignition attempts under unsafe draft conditions.
  • Install difficulty: 2/5 — Disconnect power before starting. Tools needed: 1/4" nut driver, needle-nose pliers, and a manometer or magnehelic gauge to verify post-install set point. Photograph hose routing and terminal wiring before removal. Replace pressure tubing if cracked or brittle.
  • Warranty: 1-year OEM factory warranty. In-stock and ships same business day from our warehouse.

Compatibility: Engineered for the Carrier PY3GNA042060NA packaged gas/electric unit. Also fits select Bryant and Payne models requiring a 0.18" WC draft pressure switch — verify your unit's data plate and existing switch markings before ordering. Our HVAC parts specialists are available to confirm fitment prior to purchase.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier PY3GNA042060NA?
Yes. This is the factory-specified OEM pressure switch for the Carrier PY3GNA042060NA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier PY3GNA042060NA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online