OEM Carrier Pressure Switch 0.18 WC for PY3GNA024040NA — HK06WC061
Carrier

OEM Carrier Pressure Switch 0.18 WC for PY3GNA024040NA — HK06WC061

SKU: CARRIE-PY3GNA024040NA-PRESSURE_SWITCH-HK06WC061 Brand: Carrier
Guaranteed to fit HK06WC061 — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Draft Inducer Pressure Switch 0.18" WC for Model PY3GNA024040NA

This OEM Carrier draft pressure switch (part number HK06WC061, updated replacement HK06MB061) is the factory-specified pressure proving switch for the Carrier PY3GNA024040NA packaged unit. Its job is to verify that the inducer motor is producing adequate negative pressure before allowing the control board to proceed with ignition. When this switch fails, the furnace will go into a hard lockout — typically before any ignition attempt — leaving you with a system that powers on but produces no heat.

  • Specs: 0.18" Water Column (WC) | Normally open, closes on negative pressure | Single-port design | Cross-references Honeywell IS20224-5236 | Compatible with Bryant, Carrier, and Payne platforms
  • OEM vs Generic: OEM switches are calibrated to the exact ±0.01" WC tolerance required by this unit. Off-spec generic switches can trigger nuisance lockouts or, worse, allow ignition under unsafe draft conditions — always use OEM on pressure-sensitive packaged units.
  • Install difficulty: 2/5 — Turn off power and gas before servicing. Tools needed: flathead screwdriver, 1/4" nut driver, manometer (recommended to verify draft pressure post-install). Photograph hose routing before disconnecting. The hose barb connects to the inducer housing port; ensure tubing is free of cracks or blockage.
  • Warranty: 1-year OEM factory warranty. In-stock and ships same business day from our warehouse.

Compatibility & Supersession Note: Originally sold as HK06WC061, this part has been superseded by HK06MB061 — the direct OEM replacement shipped for all new orders. Both part numbers are fully interchangeable on the Carrier PY3GNA024040NA. Also fits select Bryant and Payne packaged unit and furnace models with a 0.18" WC pressure switch specification. Verify the WC rating on your existing switch before ordering. Not sure? Our HVAC-certified team will verify fitment before you buy — contact us before placing your order.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier PY3GNA024040NA — HK06WC061?
Yes. This is the factory-specified OEM pressure switch for the Carrier PY3GNA024040NA — HK06WC061. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier PY3GNA024040NA — HK06WC061?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.