This OEM Carrier pressure switch (part number HK06WC061, superseded by HK06MB061) is the factory-specified replacement for the Carrier PY3GEAA60115NA packaged unit. The pressure switch monitors negative pressure created by the draft inducer motor to confirm safe venting conditions before the ignition sequence is allowed to proceed. When it fails or sticks open, the furnace control board never receives proof of inducer operation — resulting in a hard lockout before ignition, a blinking fault code, or a furnace that attempts to start and immediately shuts down. This is one of the most common causes of a furnace that "clicks but won't light."
Compatibility: Fits Carrier model PY3GEAA60115NA and select Bryant and Payne packaged units sharing the same inducer/pressure switch assembly. Also fits across Carrier, Bryant, and Payne furnace and packaged unit platforms using the 0.18" WC specification — verify your unit's existing switch rating on the data plate or wiring diagram before ordering. Need fitment confirmation? Our HVAC parts specialists verify compatibility before you purchase.