Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier 2-Pole Contactor 30 Amp 24V for PY2PPB060090NB
Carrier

OEM Carrier 2-Pole Contactor 30 Amp 24V for PY2PPB060090NB

SKU: CARRIE-PY2PPB060090NB-CONTACTOR-HN52KC025 Brand: Carrier
Guaranteed to fit PY2PPB060090NB — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier 2-Pole Contactor 30 Amp 24V Coil — HN52KC025 for Model PY2PPB060090NB

This OEM-grade 2-pole contactor is the factory-specified replacement for the Carrier PY2PPB060090NB packaged unit. The contactor is the high-voltage relay that your 24V thermostat signal energizes to switch power to the compressor and condenser fan. When the contactor fails — due to pitted contacts, a burned coil, or welded poles — the system either won't turn on at all, runs continuously without shutting off, or hums loudly at startup with no cooling. Replacing a faulty contactor is one of the most common and cost-effective AC repairs you can perform.

  • Specs: 2-Pole (Double Pole) | 30 Amp RES rating | 24V AC coil voltage | 50/60 Hz | Replaces OEM part number HN52KC025
  • OEM vs Generic: OEM-grade contactors meet exact Carrier factory coil pull-in voltage and contact silver-alloy specifications. Cheap generic contactors often use thinner contact material, leading to premature pitting and repeat failures within a single season.
  • Install difficulty: 2/5 — Always disconnect power at the disconnect box before servicing. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, multimeter. Photograph all wiring connections before removing the old contactor.
  • Warranty: 1-year replacement warranty. Orders placed by 3 PM local time ship the same business day from our warehouse.

Compatibility: Engineered to fit the Carrier PY2PPB060090NB packaged unit. Also cross-references with Bryant and Payne equipment using the HN52KC025 specification. Note: HN52KC025 has been superseded — this listing ships the current OEM-approved replacement. Verify your unit's data plate pole count, amp rating, and coil voltage before ordering. Our fitment team is available to confirm compatibility before you buy.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier PY2PPB060090NB?
Yes. This is the factory-specified OEM contactor for the Carrier PY2PPB060090NB. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier PY2PPB060090NB?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.