This is the genuine OEM spark electrode ignitor assembly for the Carrier PY2PPB042060AB packaged gas/electric unit. The ignitor generates the high-voltage spark that lights the burner on each call for heat. When this component fails, the control board will attempt ignition, detect no flame, and lock out the system — leaving you with a unit that runs its inducer but never fires the burner. You may also see a blinking fault code on the control board indicating an ignition failure.
Compatibility: Designed for the Carrier PY2PPB042060AB packaged rooftop/gas-electric unit. Always cross-reference the part number on your existing ignitor or your unit's wiring diagram before ordering. Our HVAC parts specialists are available to confirm fitment — contact us before you order if you have any questions.