OEM Carrier Direct Spark Ignition (DSI) Control Board LH33WP003 for Model PY2PPB042060AB

This is the genuine OEM Carrier LH33WP003 Direct Spark Ignition (DSI) control board — the factory-specified replacement for the Carrier PY2PPB042060AB packaged rooftop unit. The DSI control board is the brain of the heating system: it sequences the inducer fan, fires the spark igniter, opens the gas valve, monitors the flame sensor, and supervises all safety limit switches. When this board fails, you'll typically see a hard lockout with no ignition attempt, a furnace that sparks but never lights, or erratic short-cycling with no fault pattern. Onboard LED diagnostics help pinpoint the exact fault code before you replace any secondary component.

  • Specs: Direct Spark Ignition (DSI) microprocessor-based control | Monitors inducer, blower, and indoor fan motors | Controls spark igniter and gas valve | Flame sensing with automatic lockout protection | LED status indicators for fault code diagnostics | Dimensions: 5 × 7 × 1.875 in
  • OEM vs Generic: This OEM board is manufactured to Carrier's exact design tolerances and firmware — ensuring full compatibility with the PY2PPB042060AB's safety circuit, timing sequences, and flame-sense thresholds. Aftermarket boards may use wider tolerances that cause nuisance lockouts or missed fault detection, risking heat exchanger damage.
  • Install difficulty: 3/5 — Disconnect power and gas before beginning. Tools needed: 1/4" and 5/16" nut drivers, needle-nose pliers, phone/camera for wiring photos. Label every wire harness before removal. Verify 24V control power is restored before startup. Recommended for qualified HVAC technicians.
  • Warranty: 1-year OEM factory warranty against defects. Ships same business day from our warehouse when ordered before 3 PM local time.

Compatibility: Engineered as a direct-fit replacement for Carrier PY2PPB042060AB packaged rooftop units. Also replaces cross-reference part number LH33WP003A. Always verify your unit's data plate part number before ordering. Our HVAC parts specialists are available to confirm fitment — contact us before you buy for peace of mind.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my Carrier PY2PPB042060AB?
Yes. This is the factory-specified OEM control board for the Carrier PY2PPB042060AB. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my Carrier PY2PPB042060AB?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.