Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier 2-Pole Contactor 30A 24V for PY2PPB030060AB — HN52KC025
Carrier

OEM Carrier 2-Pole Contactor 30A 24V for PY2PPB030060AB — HN52KC025

SKU: CARRIE-PY2PPB030060AB-CONTACTOR-HN52KC025 Brand: Carrier
Guaranteed to fit HN52KC025 — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier 2-Pole Contactor 30 Amp 24V Coil for Model PY2PPB030060AB — HN52KC025

This OEM 2-pole contactor is the factory-specified replacement for the Carrier PY2PPB030060AB packaged unit. The contactor acts as the high-voltage relay that receives a 24V signal from the thermostat or control board and switches line-voltage power (240V) to the compressor and condenser fan motor. When a contactor fails, the most common symptom is an AC system that simply won't turn on — the unit may hum at the contactor but the compressor and fan remain dead. Worn or pitted contacts can also cause intermittent operation, hard starting, or premature compressor failure.

  • Specs: 2-Pole (Double Pole) | 30 Amp RES / 20 Amp FLA | 24VAC coil voltage | 50/60Hz | Tyco Electronics platform — factory-matched for Carrier equipment
  • OEM vs Generic: OEM contactors use silver-alloy contact tips rated to factory tolerances, delivering consistent arc suppression and longer service life. Generic units often use lower-grade contact materials that pit and weld prematurely, risking compressor damage.
  • Install Difficulty: 2/5 — Shut off all power at the disconnect and breaker before proceeding. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, multimeter. Always photograph wiring connections before removing the old contactor. Discharge any capacitors in the panel before working nearby.
  • Warranty: 1-year OEM factory warranty. In stock and ships same business day from our warehouse.

Compatibility: Designed for the Carrier PY2PPB030060AB packaged unit. Note: OEM part number HN52KC025 has been superseded by HN52KC024 — this listing ships the current factory-authorized replacement. Also fits many Carrier, Bryant, and Payne systems using a 2-pole 30A 24V contactor. Verify pole count, amperage, and coil voltage against your unit's wiring diagram before ordering. Our team is available to confirm fitment before you buy.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier PY2PPB030060AB — HN52KC025?
Yes. This is the factory-specified OEM contactor for the Carrier PY2PPB030060AB — HN52KC025. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier PY2PPB030060AB — HN52KC025?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online