Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier High Pressure Switch 395/295 PSI for PY2PNB060115AB
Carrier

OEM Carrier High Pressure Switch 395/295 PSI for PY2PNB060115AB

SKU: CARRIE-PY2PNB060115AB-PRESSURE_SWITCH-HK02ZA395 Brand: Carrier
Guaranteed to fit PY2PNB060115AB — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier High Pressure Switch 395/295 PSI — HK02ZA395 for Model PY2PNB060115AB

This OEM Carrier high pressure switch (part number HK02ZA395) is the factory-specified replacement for the Carrier PY2PNB060115AB packaged unit. The high pressure switch is a critical refrigerant-circuit safety device: it continuously monitors system discharge pressure and opens the control circuit to shut down the compressor if pressure climbs to an unsafe level. When this switch fails or trips, the system typically locks out on a high-pressure fault, short-cycles the compressor, or refuses to start — leaving you without cooling or heating on the hottest or coldest days of the year.

  • Specs: Opens (cutout) at 395 PSI | Closes (reset) at 295 PSI | 1/8" NPT male thread | Rated 6(6)A at 240 VAC | Pmax 41 Bar | Sensata PS80-03-0018 platform | Auto-reset type
  • OEM vs Generic: This is a genuine Carrier OEM part, factory-matched to exact cutout and reset pressures. Aftermarket switches frequently carry ±5–10% pressure tolerances that can allow nuisance trips or — worse — fail to protect the compressor at true high-pressure events.
  • Install Difficulty: 2/5 — Recover system refrigerant before removing the switch (EPA 608 required). Tools needed: refrigerant recovery unit, adjustable wrench, 1/8" NPT thread tape, manifold gauge set. Always leak-check the port after reinstallation before recharging.
  • Warranty: 1-year OEM factory warranty. Genuine Carrier part. Ships same business day from our warehouse.

Compatibility: Direct OEM replacement for Carrier model PY2PNB060115AB packaged units. Also cross-references to legacy part numbers 312926-217, 71267D1, HK02ZA380, HK02ZA396, HK02ZA400, and HK02ZA401 — confirm the 395/295 PSI cutout spec on your unit's data plate before ordering. In stock and ready to ship today — order by 3 PM for same-day dispatch.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier PY2PNB060115AB?
Yes. This is the factory-specified OEM pressure switch for the Carrier PY2PNB060115AB. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier PY2PNB060115AB?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.