This is the OEM factory-specified flame sensor for the Carrier PY2PNB030040AB gas furnace. The flame sensor — also called a flame rod — uses ionization/rectification technology to detect the presence of a burner flame during each heating cycle. When the burner ignites, the flame generates a small DC microamp signal that the control board reads as confirmation of combustion. A failed or contaminated sensor causes the board to cut gas flow as a safety measure, resulting in the furnace starting briefly then shutting off within 5–8 seconds, often triggering a lockout fault code.
Compatibility: Designed for the Carrier PY2PNB030040AB gas furnace. Always verify your existing sensor's mounting angle (90°) and connector type against your unit's data plate before ordering. Not sure if this is the right part? Our HVAC parts specialists are available to confirm fitment before you buy — order with confidence and get it shipped today.