OEM Carrier High Pressure Switch 395/295 PSI for PY2PEB060130AB
Carrier

OEM Carrier High Pressure Switch 395/295 PSI for PY2PEB060130AB

SKU: CARRIE-PY2PEB060130AB-PRESSURE_SWITCH-HK02ZA395 Brand: Carrier
Guaranteed to fit PY2PEB060130AB — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier High Pressure Switch HK02ZA395 — 395/295 PSI for Model PY2PEB060130AB

This OEM high pressure switch is the factory-specified refrigerant-side safety control for the Carrier PY2PEB060130AB packaged unit. Mounted on the high-pressure side of the refrigerant circuit, it monitors system pressure and opens the control circuit to shut down the compressor if pressure exceeds the factory-set limit, protecting against catastrophic compressor failure, refrigerant line rupture, and heat exchanger damage. Common failure symptoms include nuisance compressor lockout, system short-cycling on high pressure fault codes, or a compressor that won't start even when refrigerant charge is confirmed correct.

  • Specs: Opens at 395 PSI | Closes at 295 PSI | 1/8" NPT fine thread port | 6(6)A @ 240 VAC | Sensata PS80-03-0018 platform | PMAX 41B rated
  • OEM vs Generic: The OEM Carrier HK02ZA395 is manufactured by Sensata to exact factory cut-out tolerances (±2 PSI). Generic substitutes often carry wider tolerances that can allow unsafe pressure excursions or cause premature nuisance trips, shortening compressor life.
  • Install difficulty: 3/5 — Refrigerant-side work requires an EPA 608 certified technician. System must be recovered or isolated before replacing the switch. Tools needed: manifold gauge set, 1/8" NPT tap or flare fitting wrench, refrigerant-rated thread sealant, multimeter. Confirm system pressures are normal after reinstall before restart.
  • Warranty: 1-year OEM factory warranty. In-stock and ships same business day from our warehouse.

Compatibility: Factory replacement for Carrier model PY2PEB060130AB packaged units. Also replaces legacy part numbers 312926-217, 71267D1, HK02ZA380, HK02ZA396, HK02ZA400, HK02ZA401, HK02ZA435, HK02ZA500, and HK02ZA501. Always verify PSI ratings on your unit's data plate or wiring diagram before ordering. Our team is available to confirm fitment — reach out before you order.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier PY2PEB060130AB?
Yes. This is the factory-specified OEM pressure switch for the Carrier PY2PEB060130AB. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier PY2PEB060130AB?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.