OEM Carrier High Pressure Switch 406/300 PSI — HK02ZA395 PY2PEB060115N
Carrier

OEM Carrier High Pressure Switch 406/300 PSI — HK02ZA395 PY2PEB060115N

SKU: CARRIE-PY2PEB060115NB-PRESSURE_SWITCH-HK02ZA395 Brand: Carrier
Guaranteed to fit PY2PEB060115N — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier High Pressure Switch 406/300 PSI (HK02ZA395) for Model PY2PEB060115NB

This genuine OEM high pressure switch is the factory-specified replacement for the Carrier PY2PEB060115NB packaged unit. The high pressure switch is a critical refrigerant-circuit safety device: it continuously monitors system discharge pressure and opens the control circuit if pressure exceeds the cutout threshold, preventing compressor damage, refrigerant line failure, and catastrophic system faults. When this switch fails or becomes erratic, you'll typically see nuisance high-pressure lockouts, compressor short-cycling, or a system that trips immediately on startup even with normal operating pressures.

  • Specs: Opens (cutout) at 406 PSI | Resets (closes) at 300 PSI | 1/8″ NPT male thread connection | 240 VAC rated | SPST normally-closed | Sensata PS80-03-0018 / HK02ZA395A platform
  • OEM vs Generic: This is a genuine Carrier OEM part — factory-matched cutout and reset pressures within tight tolerances. Aftermarket switches frequently carry ±5–10% pressure variance, which can allow unsafe pressures or cause nuisance trips on a healthy system.
  • Install difficulty: 2/5 — Recover refrigerant before removing the switch (EPA Section 608 required). Tools needed: refrigerant recovery machine, manifold gauge set, adjustable wrench, PTFE thread tape. Always leak-check the port after reinstallation.
  • Warranty & Shipping: Backed by a 1-year OEM manufacturer warranty. In stock — ships same business day from our warehouse.

Compatibility: Designed for the Carrier PY2PEB060115NB packaged unit. Also replaces legacy part numbers 312926-217, 71267D1, HK02ZA380, HK02ZA396, HK02ZA400, and HK02ZA401. Always verify the cutout/reset PSI rating on your existing switch's data label before ordering. Need fitment help? Our HVAC parts specialists confirm compatibility before you buy — reach out today.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier OEM Carrier High Pressure Switch 406/300 PSI — HK02ZA395 PY2PEB060115N?
Yes. This is the factory-specified OEM pressure switch for the Carrier OEM Carrier High Pressure Switch 406/300 PSI — HK02ZA395 PY2PEB060115N. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier OEM Carrier High Pressure Switch 406/300 PSI — HK02ZA395 PY2PEB060115N?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.