OEM Carrier High Pressure Switch HK02ZA395 for Model PY2PEB060115AB

This genuine OEM high pressure switch is the factory-specified safety control for the Carrier PY2PEB060115AB packaged unit. The high pressure switch monitors refrigerant pressure on the high side of the system and cuts power to the compressor the moment pressure exceeds safe operating limits. When this switch fails or trips and won't reset, you'll typically see a system lockout, a non-cooling complaint, or fault codes pointing to high-pressure cutout — symptoms that lead many technicians directly to this component.

  • Specs: Opens at 395 PSI | Closes at 295 PSI | 1/8" NPT thread | 240 VAC rated | SPST contact configuration | Sensata PS80-03-0018 / P332-1103 equivalent
  • OEM vs Generic: This is a genuine Carrier OEM switch — factory-calibrated to exact cut-in and cut-out pressure thresholds. Aftermarket substitutes often carry wider pressure tolerances, risking nuisance trips or, worse, failure to protect the compressor from damaging overpressure events.
  • Install difficulty: 2/5 — System must be recovered and pressure-free before switch removal. Tools needed: refrigerant recovery unit, 1/8" NPT tap wrench, wire stripper, multimeter (verify continuity at rest). Always verify system pressures after reinstallation before restarting.
  • Warranty & Shipping: 1-year OEM factory warranty. Ships same business day from our warehouse. Replaces legacy part numbers: 312926-217, 71267D1, HK02ZA380, HK02ZA396, HK02ZA400, HK02ZA401, HK02ZA435.

Compatibility: Designed for the Carrier PY2PEB060115AB packaged unit. Verify refrigerant type and system high-side operating pressures against your unit's data plate before ordering. Not sure it fits? Our HVAC parts specialists confirm fitment before you buy — and every order ships the same business day.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier OEM Carrier High Pressure Switch HK02ZA395 — PY2PEB060115AB?
Yes. This is the factory-specified OEM pressure switch for the Carrier OEM Carrier High Pressure Switch HK02ZA395 — PY2PEB060115AB. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier OEM Carrier High Pressure Switch HK02ZA395 — PY2PEB060115AB?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.