Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier High Pressure Switch 395/295 PSI for PY2PEB060090AA
Carrier

OEM Carrier High Pressure Switch 395/295 PSI for PY2PEB060090AA

SKU: CARRIE-PY2PEB060090AA-PRESSURE_SWITCH-HK02ZA395 Brand: Carrier
Guaranteed to fit PY2PEB060090AA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier High Pressure Switch HK02ZA395 — 395/295 PSI for Model PY2PEB060090AA

This is the genuine OEM factory-replacement high pressure switch for the Carrier PY2PEB060090AA packaged unit. The high pressure switch is a critical refrigerant-side safety device that monitors system discharge pressure and cuts power to the compressor when pressure exceeds the rated trip point. When this switch fails or trips on a fault, you'll see symptoms like nuisance compressor shutoffs, system lockout with a high-pressure fault code, or an inability to maintain cooling on hot days. A failed or out-of-spec switch must be replaced — resetting a faulty switch without diagnosis risks compressor and heat exchanger damage.

  • Specs: Opens at 395 PSI | Closes at 295 PSI | 6(6)A @ 240 VAC | 1/8" NPT fine-thread port | Quick-connect electrical terminals | Sensata PS80-03-0018 / P332-1103 platform
  • OEM vs Generic: This OEM Carrier part (HK02ZA395) is factory-calibrated to exact trip and reset pressures. Aftermarket switches often carry wider pressure tolerances that can allow unsafe operating conditions or cause nuisance trips, leading to compressor wear or voided warranties.
  • Install difficulty: 3/5 — Refrigerant-side work. This switch is located on the high-side refrigerant line; the system must be properly recovered or isolated before disconnecting. Tools needed: manifold gauge set, refrigerant recovery equipment, adjustable wrench, multimeter. Licensed HVAC technician recommended for refrigerant handling compliance.
  • Warranty: 1-year OEM factory warranty. In stock and ships same business day from our warehouse.

Compatibility: Direct OEM replacement for Carrier model PY2PEB060090AA packaged units. Also supersedes legacy part numbers 312926-217, 71267D1, HK02ZA380, HK02ZA396, HK02ZA400, HK02ZA401, HK02ZA435, HK02ZA500, and HK02ZA501 — always verify against your unit's data plate and wiring diagram before ordering. Questions about fitment? Our HVAC parts specialists verify compatibility before you buy.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier PY2PEB060090AA?
Yes. This is the factory-specified OEM pressure switch for the Carrier PY2PEB060090AA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier PY2PEB060090AA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online