Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Single Pole 40A Contactor for PY2PEB048130AA Package Unit
Carrier

OEM Carrier Single Pole 40A Contactor for PY2PEB048130AA Package Unit

SKU: CARRIE-PY2PEB048130AA-CONTACTOR-HN52KC025 Brand: Carrier
Guaranteed to fit — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Single Pole Contactor for PY2PEB048130AA Package Unit

The contactor is the heavy-duty, electrically operated switch that delivers line voltage to the compressor and condenser fan in your Carrier PY2PEB048130AA whenever the thermostat calls for cooling. A 24-volt signal energizes the coil, which pulls the contacts closed and starts the outdoor unit. When the contactor fails, through burned and pitted contacts or a dead or chattering coil, the air conditioning stops working. Common symptoms include an outdoor unit that will not start (no cooling, compressor and fan silent), a loud hum, buzz, or rapid chattering at the unit, or contacts that have welded shut so the system runs nonstop and will not cycle off even when the thermostat is satisfied. This is a single-pole contactor with a 24VAC control coil and silver-alloy contacts rated for the unit's compressor load, commonly a 30 or 40 amp resistive rating. Always verify pole count, coil voltage, and amp rating against your original before installing. OEM matters because contact quality determines lifespan. Undersized generic contacts arc and pit faster, raising resistance and heat until they either weld shut or burn open, and a failed contactor can take out the compressor it feeds. A coil wound for the wrong voltage simply will not pull in. This OEM part matches Carrier's amp rating, coil voltage, and pole configuration exactly. Install difficulty: 3 of 5. Tools: 1/4-inch and 5/16-inch nut drivers, needle-nose pliers, a multimeter, and a phone to photograph the wiring first. Number one safety rule: open the outdoor disconnect AND the indoor breaker, then discharge the run capacitor before working nearby, because capacitors hold a potentially lethal charge even with power off. Ships same business day from our stocked warehouse on orders placed before 3 PM CST. Backed by a 1-year OEM warranty and 30-day hassle-free returns on uninstalled parts.

Compatibility

This part is compatible with Carrier model PY2PEB048130AA. Always verify the part number against your unit's data plate before ordering.

Why Choose OEM?

OEM parts are manufactured to the exact factory specifications for your unit. Generic aftermarket alternatives may fit physically but often use lower-rated components that reduce equipment life and void manufacturer warranties. When the cost difference between OEM and generic is $10-30, the OEM part is always the smarter investment on a system worth $5,000-$15,000.

Shipping & Returns

Same-day shipping on orders before 3 PM CST. Standard delivery 2-5 business days, express options available at checkout. 30-day hassle-free returns on uninstalled parts — free return shipping included. 1-year OEM factory warranty coverage.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier PY2PEB048130AA Package Unit?
Yes. This is the factory-specified OEM contactor for the Carrier PY2PEB048130AA Package Unit. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier PY2PEB048130AA Package Unit?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online