OEM Carrier 2-Pole Contactor 30 Amp 24V Coil for Model PY2PEB042060AB (HN52KC025)

This OEM-spec 2-pole contactor is the factory-authorized replacement for the Carrier PY2PEB042060AB packaged unit, originally specified under part number HN52KC025. The contactor acts as a high-voltage relay: when your thermostat calls for cooling, a low-voltage 24V signal energizes the coil, closing the contacts and sending 240V power to the compressor and condenser fan. When a contactor fails — due to worn contacts, pitting, or a burned coil — the result is an air conditioner that simply will not turn on, or one that hums without starting. Replacing a failed contactor is one of the most common and cost-effective HVAC repairs available.

  • Specs: 2-Pole (Double Pole) | 30 Amp FLA (20A RES) | 24V AC Coil | 50/60 Hz | Tyco Electronics 3100A20Q328 equivalent | Factory-matched contact rating
  • OEM vs Generic: OEM-spec contactors use silver-alloy contact tips rated for the exact amperage draw of your Carrier system. Generic contactors often use lower-grade alloys that pit and weld faster under load, shortening compressor life and risking a locked-out system.
  • Install Difficulty: 2/5 — Always shut off power at the disconnect box before servicing. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, non-contact voltage tester. Photograph all wiring terminals before disconnecting. Slide wires off old contactor and onto matching terminals of new unit — no splicing required.
  • Warranty: 1-year OEM manufacturer warranty. Ships same business day from our warehouse when ordered before 3PM local time.

Compatibility: Designed for Carrier model PY2PEB042060AB packaged units. Note: OEM part number HN52KC025 has been superseded — this listing ships the current authorized replacement (HN52KC024 / equivalent) that matches all original factory specifications. Always verify coil voltage (24V) and pole count on your unit's data plate before ordering. Our fitment team is available to confirm compatibility before you buy.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier OEM Carrier 2-Pole Contactor 30A 24V HN52KC025 — PY2PEB042060AB?
Yes. This is the factory-specified OEM contactor for the Carrier OEM Carrier 2-Pole Contactor 30A 24V HN52KC025 — PY2PEB042060AB. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier OEM Carrier 2-Pole Contactor 30A 24V HN52KC025 — PY2PEB042060AB?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.