Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier High Pressure Switch 395/295 PSI for PY2PEB036060AA
Carrier

OEM Carrier High Pressure Switch 395/295 PSI for PY2PEB036060AA

SKU: CARRIE-PY2PEB036060AA-PRESSURE_SWITCH-HK02ZA395 Brand: Carrier
Guaranteed to fit PY2PEB036060AA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier High Pressure Switch 395/295 PSI — HK02ZA395 for Model PY2PEB036060AA

This OEM Carrier high pressure switch (part number HK02ZA395) is the factory-specified refrigerant-side safety control for the Carrier PY2PEB036060AA packaged unit. The high pressure switch continuously monitors refrigerant discharge pressure and opens the safety circuit when pressure exceeds the cut-out threshold, protecting the compressor from catastrophic over-pressure failure. A failed or out-of-calibration switch will cause the system to lock out on high pressure fault, short-cycle without cooling, or in some cases allow pressure to run dangerously high without tripping — both scenarios damaging the compressor over time.

  • Specs: Cut-Out (Open) at 395 PSI | Cut-In (Close) at 295 PSI | Rated 240 VAC | 1/8" NPT male thread | Single-pole normally-closed (SPNC) | Sensata / Pressurestat series PS80
  • OEM vs Generic: OEM switches are factory-calibrated to ±2% PSI tolerance, ensuring the compressor is protected at the exact design threshold. Generic switches frequently carry ±10–15% tolerance, meaning they may fail to trip in time — or trip unnecessarily — shortening compressor life and voiding equipment warranties.
  • Install difficulty: 2/5 — Recover all refrigerant before removing the switch; never open the refrigerant circuit under pressure. Tools needed: refrigerant recovery machine, adjustable wrench, manifold gauge set, thread sealant (Nylog or equivalent). Always verify system pressures with gauges after reinstall before recharging.
  • Warranty & Shipping: Backed by Carrier's 1-year OEM parts warranty. In stock and ships same business day from our warehouse.

Compatibility: Engineered for the Carrier PY2PEB036060AA packaged unit. Also replaces OEM part numbers 312926-217, 71267D1, HK02ZA380, HK02ZA396, HK02ZA400, HK02ZA401, HK02ZA435, HK02ZA500, and HK02ZA501. Always confirm the PSI rating on your existing switch or equipment data plate before ordering. Our fitment team is available to verify compatibility before you purchase.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier PY2PEB036060AA?
Yes. This is the factory-specified OEM pressure switch for the Carrier PY2PEB036060AA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier PY2PEB036060AA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online