Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Flame Sensor 50HJ401431 for PY1RPA120224ABWA
OEM Carrier Flame Sensor 50HJ401431 for PY1RPA120224ABWA
OEM Carrier Flame Sensor 50HJ401431 for PY1RPA120224ABWA
OEM Carrier Flame Sensor 50HJ401431 for PY1RPA120224ABWA
Carrier

OEM Carrier Flame Sensor 50HJ401431 for PY1RPA120224ABWA

SKU: CARRIE-PY1RPA120224ABWA-FLAME_SENSOR-50HJ401431 Brand: Carrier
Guaranteed to fit PY1RPA120224ABWA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Flame Sensor 50HJ401431 for Model PY1RPA120224ABWA

This is the genuine OEM Carrier flame sensor (part #50HJ401431), factory-specified for the Carrier PY1RPA120224ABWA packaged gas heating unit. The flame sensor is a critical safety component: after ignition, the control board sends a small microamp current through the sensor's stainless steel rod into the burner flame. If the board does not detect that return current within a few seconds, it cuts gas flow and locks out the system. A failed or carbon-coated flame sensor is one of the most common causes of a furnace that lights briefly, then shuts off after 5–8 seconds — often followed by a lockout fault code.

  • Specs: OEM part #50HJ401431 | Stainless steel sensing rod with alumina-coated probe | Dimensions approx. 2.9" W × 4" D × 1.75" H | Compatible with standard 24V AC furnace control circuits | Weight: 0.09 lbs
  • OEM vs Generic: This is a genuine Carrier OEM part, not an aftermarket substitute. OEM sensors are calibrated to the exact microamp detection threshold required by the Carrier control board. Generic sensors with off-spec rod coatings or bracket geometry can cause nuisance lockouts or, worse, unreliable flame detection.
  • Install Difficulty: 2/5 — Shut off gas supply and 120V power before beginning. The sensor is typically secured by a single 1/4" hex-head screw. Tools needed: 1/4" nut driver, needle-nose pliers, fine steel wool or emery cloth (to clean rod if reusing). Photograph wiring connector orientation before disconnecting. Total job time: 15–30 minutes.
  • Warranty: 1-year OEM manufacturer warranty. In-stock units ship same business day when ordered by cutoff time.

Compatibility: Engineered as a direct OEM drop-in replacement for the Carrier PY1RPA120224ABWA packaged gas/electric unit. Always confirm your existing part number against the unit data plate or wiring diagram before ordering. Our parts specialists are available to verify fitment — contact us before you buy if you have any questions.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Flame Sensor fit my Carrier PY1RPA120224ABWA?
Yes. This is the factory-specified OEM flame sensor for the Carrier PY1RPA120224ABWA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the flame sensor on my Carrier PY1RPA120224ABWA?
Difficulty: Easy (10–15 min)
Step 1: Turn off power/gas. Step 2: Open furnace panel. Step 3: Locate flame sensor rod near burners. Step 4: Remove single mounting screw. Step 5: Clean rod with 400-grit sandpaper until shiny (or replace). Step 6: Reinstall and tighten. Most common furnace repair — saves $150–$300 vs technician.
My furnace lights then shuts off after a few seconds. Why?
Furnace lights then shuts off after 3–10 seconds = dirty flame sensor in 90% of cases. The sensor can’t detect flame through oxidation buildup. Fix: clean with 400-grit sandpaper (free, 15 min). If cleaning doesn’t work, replace the sensor.
Is this flame sensor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier flame sensor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online