This OEM pressure switch (part number HK02ZB044) is the factory-specified replacement for the Carrier PY1RPA090125ACWB packaged gas/electric unit. The pressure switch monitors the inducer draft motor's negative pressure to confirm safe flue gas venting before allowing the ignition sequence to proceed. When this switch fails, the furnace or packaged unit will lock out before ignition — often resulting in a no-heat call with a pressure switch fault code on the control board. A faulty switch may also cause the unit to short-cycle, repeatedly attempt ignition, or fail to advance past the inducer pre-purge stage.
Compatibility: Direct OEM replacement for Carrier model PY1RPA090125ACWB packaged gas/electric unit. Verify the PSI rating (7# open / 22# close) and lead length (50") against your unit's data plate and existing switch label before ordering. Our HVAC parts specialists are available to confirm fitment prior to purchase — contact us before you order.