Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Flame Sensor 90° for PY1PPB060130AAAA — 48GS400192
OEM Carrier Flame Sensor 90° for PY1PPB060130AAAA — 48GS400192
OEM Carrier Flame Sensor 90° for PY1PPB060130AAAA — 48GS400192
OEM Carrier Flame Sensor 90° for PY1PPB060130AAAA — 48GS400192
Carrier

OEM Carrier Flame Sensor 90° for PY1PPB060130AAAA — 48GS400192

SKU: CARRIE-PY1PPB060130AAAA-FLAME_SENSOR-48GS400192 Brand: Carrier
Guaranteed to fit 48GS400192 — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Flame Sensor 48GS400192 for Model PY1PPB060130AAAA

This OEM 90-degree flame sensor is the factory-specified replacement for the Carrier PY1PPB060130AAAA gas furnace. The flame sensor (also called a flame rod) uses ionization/rectification technology to confirm burner ignition during each heating cycle. When working correctly, it allows the gas valve to stay open and the furnace to run normally. When it fails — typically due to oxidation or carbon buildup on the sensing rod — the control board cannot verify a flame is present and shuts off the gas valve as a safety precaution, causing the furnace to lock out after 5–8 seconds of attempted operation.

  • Specs: OEM Part # 48GS400192 | 90-degree mounting bracket | Rod length approx. 1.6 in. | Overall dimensions approx. 4.9 in. × 1.75 in. | Factory-matched to Carrier IFC control board signal thresholds
  • OEM vs Generic: This is a genuine Carrier OEM part, manufactured to exact factory tolerances. Generic flame sensors may have inconsistent rod coatings and signal outputs that cause nuisance lockouts or premature failure — especially in high-efficiency furnaces where the control board has a narrow microamp acceptance window.
  • Install difficulty: 2/5 — Turn off power and gas before beginning. Tools needed: 1/4" hex driver or nut driver, needle-nose pliers, and a multimeter (to verify microamp output post-install). Disconnect the single wire connector, remove the one mounting screw, swap the sensor, and reconnect. Always verify proper operation through a full heating cycle after install.
  • Warranty: 1-year OEM manufacturer warranty against defects. Ships same business day from our warehouse when ordered before cutoff.

Compatibility: Designed for the Carrier PY1PPB060130AAAA gas furnace. This 90-degree bracket style is the direct OEM replacement — verify your existing sensor's bracket angle and connector type before ordering. Our fitment team is available to confirm compatibility if you have any questions before purchasing.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Flame Sensor fit my Carrier PY1PPB060130AAAA — 48GS400192?
Yes. This is the factory-specified OEM flame sensor for the Carrier PY1PPB060130AAAA — 48GS400192. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the flame sensor on my Carrier PY1PPB060130AAAA — 48GS400192?
Difficulty: Easy (10–15 min)
Step 1: Turn off power/gas. Step 2: Open furnace panel. Step 3: Locate flame sensor rod near burners. Step 4: Remove single mounting screw. Step 5: Clean rod with 400-grit sandpaper until shiny (or replace). Step 6: Reinstall and tighten. Most common furnace repair — saves $150–$300 vs technician.
My furnace lights then shuts off after a few seconds. Why?
Furnace lights then shuts off after 3–10 seconds = dirty flame sensor in 90% of cases. The sensor can’t detect flame through oxidation buildup. Fix: clean with 400-grit sandpaper (free, 15 min). If cleaning doesn’t work, replace the sensor.
Is this flame sensor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier flame sensor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online