OEM Carrier 2-Pole Contactor 30 Amp 24V for PY1PPB060115AAAA
Carrier

OEM Carrier 2-Pole Contactor 30 Amp 24V for PY1PPB060115AAAA

SKU: CARRIE-PY1PPB060115AAAA-CONTACTOR-HN52KC025 Brand: Carrier
Guaranteed to fit PY1PPB060115AAAA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier 2-Pole Contactor 30 Amp 24V Coil — Model PY1PPB060115AAAA (HN52KC025)

This OEM contactor is the factory-specified replacement for the Carrier PY1PPB060115AAAA packaged unit. The contactor acts as a high-voltage relay, using a low-voltage 24V control signal from the thermostat to close a circuit that powers the compressor and condenser fan motor. When the contactor fails — due to pitted or welded contacts, a burnt coil, or worn contact tips — the most common symptom is an air conditioner that won't turn on at all, or one that runs continuously even when cooling is not called for.

  • Specs: 2-Pole (Double Pole) | 30 Amp RES rating | 24V AC coil | Definite Purpose contactor | Factory-matched Tyco Electronics design
  • OEM vs Generic: OEM contactors are built to exact factory contact gap and coil pull-in specifications. Generic units frequently use lower-grade silver alloy contacts that pit faster under repeated cycling, shortening service life significantly in high-demand climates.
  • Install difficulty: 3/5 — Always disconnect power at the disconnect box and verify zero voltage before touching any wiring. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, multimeter. Photograph all wire connections before removal. Note: discharge any capacitors in the unit before working in the control panel.
  • Warranty: 1-year OEM factory warranty against defects in materials and workmanship. Ships same business day from our warehouse.

Compatibility: Engineered for the Carrier PY1PPB060115AAAA packaged unit. OEM part number HN52KC025 (superseded by HN52KC024 — fully interchangeable). Also cross-references to Carrier, Bryant, and Payne systems using a 2-pole, 30-amp, 24V coil contactor. Confirm your unit's data plate voltage and amperage before ordering — our team is happy to verify fitment. Order now and your part ships today.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier PY1PPB060115AAAA?
Yes. This is the factory-specified OEM contactor for the Carrier PY1PPB060115AAAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier PY1PPB060115AAAA?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.