OEM Carrier Direct Spark Ignition (DSI) Control Board LH33WP003 for Model PY1PPA036120ACBA

This is the genuine OEM Carrier Direct Spark Ignition (DSI) control board, part number LH33WP003, factory-specified for the Carrier PY1PPA036120ACBA packaged rooftop unit. As the central brain of your system's heating sequence, this integrated ignition control board manages spark ignition, gas valve activation, combustion air and blower motor sequencing, flame sensing, and safety lockout — all in one precision-engineered module. When this board fails, symptoms typically include no-heat calls, repeated ignition lockout faults, short cycling, or complete loss of system response after a call for heat.

  • Specs: Direct Spark Ignition (DSI) microprocessor-based control | Manages combustion, blower, and indoor fan motors | Integrated spark igniter and gas valve output control | Onboard LED fault-code diagnostics for rapid troubleshooting
  • OEM vs Generic: This is a genuine Carrier OEM board — not an aftermarket substitute. OEM boards are programmed to exact factory timing sequences for ignition trial, flame proving, and lockout thresholds. Generic boards may use approximated timing that triggers nuisance lockouts or voids equipment warranties.
  • Install difficulty: 3/5 — Disconnect power and gas before servicing. Photograph all wiring harness connections before removal. Tools needed: ¼" nut driver, needle-nose pliers, phone camera. Board mounts with standard sheet-metal screws; wiring connectors are keyed to prevent misconnection. Always verify for fault codes with a multimeter before condemning the board.
  • Warranty: 1-year OEM manufacturer warranty. Ships same business day from our warehouse when ordered before 3 PM local time.

Compatibility: Engineered as a direct factory replacement for the Carrier PY1PPA036120ACBA packaged rooftop unit. Also fits select additional Carrier, Bryant, and ICP commercial rooftop models that specify the LH33WP003 DSI control board — verify your unit's data plate and wiring diagram before ordering. Not sure if this is the right part? Contact our HVAC parts specialists and we'll confirm fitment before you buy. In stock — order now and this ships today.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my Carrier PY1PPA036120ACBA?
Yes. This is the factory-specified OEM control board for the Carrier PY1PPA036120ACBA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my Carrier PY1PPA036120ACBA?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.