Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier 2-Pole Contactor 30 Amp 24V for PY1PPA036120ACBA
Carrier

OEM Carrier 2-Pole Contactor 30 Amp 24V for PY1PPA036120ACBA

SKU: CARRIE-PY1PPA036120ACBA-CONTACTOR-HN52KC025 Brand: Carrier
Guaranteed to fit PY1PPA036120ACBA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier 2-Pole Contactor 30 Amp 24V Coil — HN52KC025 for Model PY1PPA036120ACBA

This OEM contactor is the factory-specified replacement for the Carrier PY1PPA036120ACBA condenser unit. The contactor acts as a high-voltage relay, using a low-voltage 24V thermostat signal to switch the high-voltage circuit that powers the compressor and condenser fan motor. When the contactor fails — due to pitted contacts, a stuck plunger, or a burned coil — the system will either fail to start entirely, run continuously without shutting off, or trip the breaker on startup.

  • Specs: 2-Pole (Double Pole) | 30 Amp RES / 20 Amp FLA | 24V AC Coil | 50/60 Hz | Factory-matched Tyco Electronics design
  • OEM vs Generic: OEM contactors feature silver-alloy contact points rated to exact factory ampacity. Generic contactors often use inferior alloys that pit faster under the repeated high-current switching load of a residential compressor.
  • Install Difficulty: 2/5 — Shut off power at the breaker and disconnect panel before beginning. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, multimeter. Photograph all wiring connections before removing the old contactor. Note: always verify coil voltage and pole count match before installing.
  • Warranty: 1-year OEM factory warranty. In-stock and ships same business day from our warehouse.

Compatibility: Designed for Carrier model PY1PPA036120ACBA condensers. Also compatible across a wide range of Carrier, Bryant, and Payne condenser units specifying a 2-pole, 30 Amp, 24V coil contactor. Always verify pole count, amperage, and coil voltage against your unit's data plate before ordering. Need help confirming fitment? Our HVAC parts specialists verify compatibility before you order — contact us today and ship the same day.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier PY1PPA036120ACBA?
Yes. This is the factory-specified OEM contactor for the Carrier PY1PPA036120ACBA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier PY1PPA036120ACBA?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.