OEM Carrier Direct Spark Ignition (DSI) Control Board LH33WP003 for Model PY1PPA030060ADBA

This is the genuine OEM Carrier Direct Spark Ignition (DSI) Control Board (part number LH33WP003), factory-specified for the Carrier PY1PPA030060ADBA packaged rooftop unit. The DSI control board is the operational brain of your unit's heating system — it manages spark ignition sequencing, gas valve activation, inducer and blower motor operation, flame sensing, and safety lockout logic. When this board fails, common symptoms include a no-heat call with no ignition attempt, the system entering hard lockout after repeated failed ignition trials, or the unit shutting down within seconds of a heat call due to a false flame-sense fault. Replacing with the correct OEM board ensures factory-timed sequencing and full safety compliance.

  • Specs: Direct Spark Ignition (DSI) microprocessor-based board | Control voltage: 24 VAC (18–30 VAC), 60 Hz | Line voltage: 208/230 VAC, 60 Hz | Pre-purge: 45 sec | Trial for ignition: 5+2 sec | Retry period: every 20 sec for 15 min | Lockout: manual reset | Post-purge: 45 sec | LED fault-code diagnostics
  • OEM vs. Generic: This is the genuine Carrier factory board, built to exact design tolerances. Aftermarket boards (e.g., ICM291) offer a lower-cost alternative but may exhibit timing variances that can cause nuisance lockouts or void equipment warranties. OEM is always recommended for commercial rooftop applications.
  • Install difficulty: 3/5 — Disconnect all power before servicing. Tools needed: Phillips and flathead screwdrivers, needle-nose pliers, phone or camera to photograph all wiring harness connections before removal. Verify 24 VAC transformer output before condemning the board. Recommended for qualified HVAC technicians.
  • Warranty: 1-year OEM factory warranty. Ships same business day from our warehouse when ordered before 3 PM local time.

Compatibility: Designed for the Carrier PY1PPA030060ADBA packaged rooftop unit. Also cross-references to part suffix variant LH33WP003A. Verify your unit's data plate and existing board part number before ordering. Our HVAC parts specialists are available to confirm fitment — contact us before you order for peace of mind. In stock and ready to ship today.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my Carrier PY1PPA030060ADBA?
Yes. This is the factory-specified OEM control board for the Carrier PY1PPA030060ADBA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my Carrier PY1PPA030060ADBA?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.