Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Silicon Carbide Hot Surface Igniter for PY1PPA030040ACBA
Carrier

OEM Carrier Silicon Carbide Hot Surface Igniter for PY1PPA030040ACBA

SKU: CARRIE-PY1PPA030040ACBA-IGNITER-LH33WZ008 Brand: Carrier
Guaranteed to fit PY1PPA030040ACBA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Silicon Carbide Hot Surface Igniter for PY1PPA030040ACBA

The hot surface igniter is the ignition source for your Carrier PY1PPA030040ACBA gas furnace. On every heat call it heats past 2,000°F to light the burner gas. When the element weakens, cracks, or burns through, the classic symptom is no heat: the inducer motor spins up, the gas valve clicks, but the burners never light and the furnace locks out after three failed trials. Homeowners often report short-cycling, cold air from the registers, a clicking sound with no "whoosh," or a furnace that runs the blower but never warms the house. This is a 120V silicon carbide hot surface igniter. A healthy element reads roughly 40–75 ohms cold on a multimeter; an open-loop (OL) reading confirms a failed igniter. Silicon carbide is the OEM material for this Carrier platform — it reaches ignition temperature quickly and seats to the burner with factory geometry. OEM matters here because ignition timing is unforgiving. Generic igniters with the wrong resistance won't glow hot enough within the board's trial window, causing repeated lockouts, or they run too hot and fail within a season. Cheaper silicon nitride or off-spec elements may not match the mounting bracket, leaving the tip mispositioned over the burner port. This OEM part restores exact resistance, temperature, and fit. Install difficulty: 2/5. Tools needed: 1/4" nut driver and a multimeter for verification. #1 safety warning: shut off the gas supply and kill power at the breaker before servicing — the igniter ceramic is also brittle, so never touch the element with bare fingers. Ships same business day from our stocked warehouse on orders placed before 3 PM CST. Backed by a 1-year OEM warranty and 30-day hassle-free returns on uninstalled parts.

Compatibility

This part is compatible with Carrier model PY1PPA030040ACBA. Always verify the part number against your unit's data plate before ordering.

Why Choose OEM?

OEM parts are manufactured to the exact factory specifications for your unit. Generic aftermarket alternatives may fit physically but often use lower-rated components that reduce equipment life and void manufacturer warranties. When the cost difference between OEM and generic is $10-30, the OEM part is always the smarter investment on a system worth $5,000-$15,000.

Shipping & Returns

Same-day shipping on orders before 3 PM CST. Standard delivery 2-5 business days, express options available at checkout. 30-day hassle-free returns on uninstalled parts — free return shipping included. 1-year OEM factory warranty coverage.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my Carrier PY1PPA030040ACBA?
Yes. This is the factory-specified OEM igniter for the Carrier PY1PPA030040ACBA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my Carrier PY1PPA030040ACBA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.