Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Flame Sensor Assembly 64.5
OEM Carrier Flame Sensor Assembly 64.5
OEM Carrier Flame Sensor Assembly 64.5
OEM Carrier Flame Sensor Assembly 64.5
Carrier

OEM Carrier Flame Sensor Assembly 64.5" Wire for PY1PEA060120ADBA

SKU: CARRIE-PY1PEA060120ADBA-FLAME_SENSOR-LH33WZ005 Brand: Carrier
Guaranteed to fit PY1PEA060120ADBA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Flame Sensor Assembly LH33WZ005 for Model PY1PEA060120ADBA

This OEM Carrier flame sensor assembly (part# LH33WZ005) is the factory-specified replacement for the Carrier PY1PEA060120ADBA packaged unit. The flame sensor — also called a flame rod — monitors the burner during each ignition cycle using a small DC microamp current passed through the flame. When the control board detects that signal, it confirms combustion is active and holds the gas valve open. A failed or contaminated flame sensor causes the furnace to light, run briefly for 5–8 seconds, then shut down and lock out — often with a diagnostic fault code indicating "flame lost" or "no flame sense." Cleaning may temporarily restore function, but a failed rod or cracked ceramic insulator requires full replacement.

  • Part Number: LH33WZ005 | Factory Authorized Parts (FAP) | Carrier OEM | Includes 64.5" wire lead with connector — direct plug-in replacement, no splicing required
  • OEM vs Generic: OEM flame sensors are manufactured to Carrier's exact microamp sensitivity threshold and ceramic insulator spec. Generic sensors often exhibit drift in sensitivity that causes nuisance lockouts or — more critically — delayed flame detection, which compromises safety system response time.
  • Install Difficulty: 2/5 — Single mounting screw and one wire connector. Tools needed: 1/4" or 5/16" nut driver, needle-nose pliers. Always disconnect power and shut off gas before servicing. Locate sensor in the burner box near the heat exchanger opening; the rod extends into the burner flame path.
  • Warranty: 1-year OEM factory warranty. In stock — ships same business day from our warehouse.

Compatibility: Engineered for Carrier model PY1PEA060120ADBA. Verify your existing part number against the unit's data plate or wiring diagram before ordering — our parts specialists are available to confirm fitment at no charge. Order by 3PM local time for same-day dispatch.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Flame Sensor fit my Carrier PY1PEA060120ADBA?
Yes. This is the factory-specified OEM flame sensor for the Carrier PY1PEA060120ADBA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the flame sensor on my Carrier PY1PEA060120ADBA?
Difficulty: Easy (10–15 min)
Step 1: Turn off power/gas. Step 2: Open furnace panel. Step 3: Locate flame sensor rod near burners. Step 4: Remove single mounting screw. Step 5: Clean rod with 400-grit sandpaper until shiny (or replace). Step 6: Reinstall and tighten. Most common furnace repair — saves $150–$300 vs technician.
My furnace lights then shuts off after a few seconds. Why?
Furnace lights then shuts off after 3–10 seconds = dirty flame sensor in 90% of cases. The sensor can’t detect flame through oxidation buildup. Fix: clean with 400-grit sandpaper (free, 15 min). If cleaning doesn’t work, replace the sensor.
Is this flame sensor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier flame sensor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.