This is the OEM factory-specified flame sensor (flame rod) for the Carrier PY1PEA048080AFBA packaged gas/electric unit. The flame sensor's job is critical: it detects the presence of a burner flame by passing a small electrical current through the rod and into the flame itself. If the control board doesn't detect that current within a few seconds of ignition, it shuts off the gas valve as a safety measure. A coated, corroded, or failed sensor is one of the most common causes of a furnace that lights, runs briefly for 5–8 seconds, then shuts down and locks out — cycling repeatedly without ever sustaining heat.
Compatibility: Designed for the Carrier PY1PEA048080AFBA 4-ton 80,000 BTU packaged gas/electric unit. Verify your existing sensor's part number on the label or your unit's wiring diagram before ordering. Our fitment specialists are available to confirm compatibility — just reach out before you buy. In stock and ships today.