Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Flame Sensor LH33WZ005 for PY1PEA048080AFBA
OEM Carrier Flame Sensor LH33WZ005 for PY1PEA048080AFBA
OEM Carrier Flame Sensor LH33WZ005 for PY1PEA048080AFBA
OEM Carrier Flame Sensor LH33WZ005 for PY1PEA048080AFBA
Carrier

OEM Carrier Flame Sensor LH33WZ005 for PY1PEA048080AFBA

SKU: CARRIE-PY1PEA048080AFBA-FLAME_SENSOR-LH33WZ005 Brand: Carrier
Guaranteed to fit PY1PEA048080AFBA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Flame Sensor LH33WZ005 for Model PY1PEA048080AFBA

This is the OEM factory-specified flame sensor (flame rod) for the Carrier PY1PEA048080AFBA packaged gas/electric unit. The flame sensor's job is critical: it detects the presence of a burner flame by passing a small electrical current through the rod and into the flame itself. If the control board doesn't detect that current within a few seconds of ignition, it shuts off the gas valve as a safety measure. A coated, corroded, or failed sensor is one of the most common causes of a furnace that lights, runs briefly for 5–8 seconds, then shuts down and locks out — cycling repeatedly without ever sustaining heat.

  • Specs: OEM Part Number LH33WZ005 | Factory-matched flame rod geometry and ceramic insulator | Correct bracket mounting configuration for Carrier packaged units
  • OEM vs Generic: OEM sensors use the exact rod alloy and ceramic insulator specification Carrier's control board expects. Off-brand sensors can produce weaker microamp signals, causing nuisance lockouts even with a clean rod — OEM eliminates that variable entirely.
  • Install Difficulty: 2/5 — Turn off gas and power at the disconnect before servicing. Tools needed: 1/4" or 5/16" nut driver, needle-nose pliers. Simply unplug the single wire connector, remove the mounting screw, swap the sensor, and reconnect. Always verify microamp reading (1.5–4.0 µA typical) with a multimeter after installation.
  • Warranty: 1-year OEM factory warranty. Ships same business day from our warehouse when ordered before cutoff.

Compatibility: Designed for the Carrier PY1PEA048080AFBA 4-ton 80,000 BTU packaged gas/electric unit. Verify your existing sensor's part number on the label or your unit's wiring diagram before ordering. Our fitment specialists are available to confirm compatibility — just reach out before you buy. In stock and ships today.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Flame Sensor fit my Carrier PY1PEA048080AFBA?
Yes. This is the factory-specified OEM flame sensor for the Carrier PY1PEA048080AFBA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the flame sensor on my Carrier PY1PEA048080AFBA?
Difficulty: Easy (10–15 min)
Step 1: Turn off power/gas. Step 2: Open furnace panel. Step 3: Locate flame sensor rod near burners. Step 4: Remove single mounting screw. Step 5: Clean rod with 400-grit sandpaper until shiny (or replace). Step 6: Reinstall and tighten. Most common furnace repair — saves $150–$300 vs technician.
My furnace lights then shuts off after a few seconds. Why?
Furnace lights then shuts off after 3–10 seconds = dirty flame sensor in 90% of cases. The sensor can’t detect flame through oxidation buildup. Fix: clean with 400-grit sandpaper (free, 15 min). If cleaning doesn’t work, replace the sensor.
Is this flame sensor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier flame sensor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.