OEM Carrier Flame Sensor LH33WZ003 for Model PY1PEA042060ADBA

This OEM flame sensor (part number LH33WZ003) is the factory-specified replacement for the Carrier PY1PEA042060ADBA packaged gas unit. The flame sensor — also called a flame rod or flame electrode — monitors the burner and sends a microamp signal to the control board confirming combustion is present. When the sensor fails or becomes coated with oxidation, the board cannot verify the flame, triggering a safety lockout. The classic symptom: the furnace or packaged unit lights, runs for 5 to 8 seconds, then shuts off and enters lockout — repeating the cycle with no heat delivered.

  • Part Type: Direct Spark Ignition (DSI) flame sensor electrode | Factory Authorized Parts (FAP) designation | Replaces LH33WZ003A and LH33WZ001 | For use with LH33WP001 ignitor
  • OEM vs Generic: This is a genuine Carrier OEM part, manufactured to exact factory tolerances for rod length, ceramic insulator quality, and microamp output. Aftermarket sensors can produce inconsistent microamp readings, causing nuisance lockouts even with a healthy burner.
  • Install Difficulty: 2/5 — Shut off gas and power before servicing. Tools needed: 1/4" or 5/16" nut driver, needle-nose pliers, multimeter (to verify microamp draw, typically 1.5–4 µA DC). Clean the rod with fine steel wool if reusing; replace if cracked or heavily oxidized.
  • Warranty: 1-year OEM factory warranty. Ships same business day from our warehouse when ordered before cutoff.

Compatibility: Engineered for the Carrier PY1PEA042060ADBA packaged gas/electric unit. Verify your existing sensor's mounting bracket configuration and wire lead length before ordering. Our team is available to confirm fitment — just reach out before you buy. Order now and ship today.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Flame Sensor fit my Carrier PY1PEA042060ADBA?
Yes. This is the factory-specified OEM flame sensor for the Carrier PY1PEA042060ADBA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the flame sensor on my Carrier PY1PEA042060ADBA?
Difficulty: Easy (10–15 min)
Step 1: Turn off power/gas. Step 2: Open furnace panel. Step 3: Locate flame sensor rod near burners. Step 4: Remove single mounting screw. Step 5: Clean rod with 400-grit sandpaper until shiny (or replace). Step 6: Reinstall and tighten. Most common furnace repair — saves $150–$300 vs technician.
My furnace lights then shuts off after a few seconds. Why?
Furnace lights then shuts off after 3–10 seconds = dirty flame sensor in 90% of cases. The sensor can’t detect flame through oxidation buildup. Fix: clean with 400-grit sandpaper (free, 15 min). If cleaning doesn’t work, replace the sensor.
Is this flame sensor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier flame sensor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.