OEM Carrier Defrost Control Board HK32EA001 for PH4RNG036000BAAA
Carrier

OEM Carrier Defrost Control Board HK32EA001 for PH4RNG036000BAAA

SKU: CARRIE-PH4RNG036000BAAA-CONTROL_BOARD-HK32EA001 Brand: Carrier
Guaranteed to fit PH4RNG036000BAAA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Defrost Control Board HK32EA001 for Model PH4RNG036000BAAA

This is the genuine OEM factory-replacement defrost control board for the Carrier PH4RNG036000BAAA heat pump. The defrost control board monitors outdoor coil conditions and governs when the unit enters and exits its defrost cycle — a critical function in heat pump operation. When the board fails, you'll typically see the outdoor coil ice over completely, the system stuck in defrost mode, or a total loss of heating capacity as the unit cannot recover from frost buildup. Cross-reference part numbers include CEPL130524-01, CEBD430524-06A, 1173636, and 1177927.

  • Part Number: HK32EA001 | OEM Carrier Factory Authorized Parts | Also supersedes HK32EA007 in most applications
  • OEM vs Generic: Genuine OEM boards are factory-calibrated for precise defrost timing intervals (30/60/90 min). Generic aftermarket boards frequently ship with incorrect timing tolerances, causing short-cycling, premature compressor wear, and voided equipment warranties.
  • Install Difficulty: 3/5 — Disconnect power at the disconnect box and verify zero voltage with a multimeter before touching the board. Tools needed: 1/4" nut driver, needle-nose pliers, multimeter, camera/phone to document wiring positions. Note defrost time selection jumper position before removal.
  • Warranty: 1-year OEM manufacturer warranty. Verified in-stock — ships same business day from our warehouse.

Compatibility: Designed as the factory-specified defrost control board for the Carrier PH4RNG036000BAAA 3-ton heat pump. Also fits select Bryant and Payne heat pump models using the HK32EA001 board. Always verify your existing board's part number on the label before ordering. Need fitment confirmation? Our HVAC parts specialists verify compatibility before you buy — contact us before placing your order.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my Carrier PH4RNG036000BAAA?
Yes. This is the factory-specified OEM control board for the Carrier PH4RNG036000BAAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my Carrier PH4RNG036000BAAA?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.