Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Contactor for PH4GNAA36000AA Packaged Heat Pump
Carrier

OEM Carrier Contactor for PH4GNAA36000AA Packaged Heat Pump

SKU: CARRIE-PH4GNAA36000AA-CONTACTOR-HN51KC024 Brand: Carrier
Guaranteed to fit — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Contactor for PH4GNAA36000AA Packaged Heat Pump

The contactor is the high-voltage switch that powers your Carrier PH4GNAA36000AA's compressor and outdoor fan motor. When the thermostat calls, the control board sends 24V to the contactor coil, the contacts pull in, and line voltage flows to the compressor. A worn contactor is one of the most common no-cool/no-heat failures: you'll hear a loud hum or chatter at the unit, see pitted or welded contacts that won't drop out (the compressor runs nonstop), or the contactor won't pull in at all so the fan and compressor stay dead while the indoor blower runs. This OEM contactor matches the pole configuration and ratings the PH4GNAA36000AA was built with. Confirm pole count (single vs double pole), contact amperage rating (typically 30–40 FLA class), and that the coil is 24V before installing. Matching the contact rating to the compressor's locked-rotor amps is what keeps the contacts from arcing and pitting under inrush. Why OEM: aftermarket contactors frequently use undersized silver-alloy contacts and lighter springs. Undersized contacts pit and weld faster under the compressor's high inrush current, and a weak coil can drop out under voltage sag, causing rapid chatter that destroys both the contactor and the compressor windings. The OEM part is rated for your unit's actual load. Install difficulty: 2/5. Tools: 1/4" and 5/16" nut drivers, flat screwdriver, multimeter, and a photo of the wiring. #1 safety warning: KILL THE BREAKER and the outdoor disconnect before touching the contactor — line voltage is always present on the line side, and the run capacitor nearby can hold a lethal charge, so discharge it before working in the cabinet. Ships same business day from our stocked warehouse on orders before 3 PM CST. 1-year OEM warranty and 30-day hassle-free returns on uninstalled parts.

Compatibility

This part is compatible with Carrier model PH4GNAA36000AA. Always verify the part number against your unit's data plate before ordering.

Why Choose OEM?

OEM parts are manufactured to the exact factory specifications for your unit. Generic aftermarket alternatives may fit physically but often use lower-rated components that reduce equipment life and void manufacturer warranties. When the cost difference between OEM and generic is $10-30, the OEM part is always the smarter investment on a system worth $5,000-$15,000.

Shipping & Returns

Same-day shipping on orders before 3 PM CST. Standard delivery 2-5 business days, express options available at checkout. 30-day hassle-free returns on uninstalled parts — free return shipping included. 1-year OEM factory warranty coverage.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier PH4GNAA36000AA Packaged Heat Pump?
Yes. This is the factory-specified OEM contactor for the Carrier PH4GNAA36000AA Packaged Heat Pump. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier PH4GNAA36000AA Packaged Heat Pump?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.