Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Condenser Definite Purpose Contactor for PH4ANG042000BCAA
Carrier

OEM Carrier Condenser Definite Purpose Contactor for PH4ANG042000BCAA

SKU: CARRIE-PH4ANG042000BCAA-CONTACTOR-HN51KC024 Brand: Carrier
Guaranteed to fit PH4ANG042000BCAA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Condenser Definite Purpose Contactor for PH4ANG042000BCAA

The contactor is the electrical switch that lets your thermostat energize the compressor and condenser fan in the Carrier PH4ANG042000BCAA package unit. When the call for cooling comes, the 24V coil pulls the contacts closed and sends line voltage to the high-current loads. When this part fails, you'll see classic symptoms: a loud chattering or buzzing at the outdoor unit, the system that won't start at all (open contacts), the unit that won't shut off because the contacts have welded together, or visible pitting and arcing burns on the contact faces causing intermittent cooling. This is a direct-replacement definite-purpose contactor matched to the original Carrier spec: correct pole configuration, a 24V control coil, and a contact amperage rating sized to this unit's compressor and fan FLA. Definite-purpose contactors are rated for the continuous-duty switching HVAC demands — do not substitute a general-purpose relay. Why OEM matters here: cheap aftermarket contactors often use undersized or lower-grade silver-alloy contacts that pit and burn faster under the inrush of compressor starts. Pitted contacts raise resistance, generate heat, and eventually weld closed or fail open — taking out the new contactor and stressing the compressor with low or chattering voltage. The OEM-spec contact rating holds up to the unit's real-world cycling. Installation difficulty: 2/5. Tools needed: 1/4" nut driver, a Phillips screwdriver, a multimeter to confirm coil continuity and contact closure, and a phone photo of the wiring before you start. #1 safety warning: turn off power at the outdoor disconnect AND the breaker before touching the contactor — line voltage is present on the contact terminals even when the unit is idle. Ships same business day from our stocked warehouse on orders placed before 3 PM CST. Backed by a 1-year OEM warranty and 30-day hassle-free returns on uninstalled parts.

Compatibility

This part is compatible with Carrier model PH4ANG042000BCAA. Always verify the part number against your unit's data plate before ordering.

Why Choose OEM?

OEM parts are manufactured to the exact factory specifications for your unit. Generic aftermarket alternatives may fit physically but often use lower-rated components that reduce equipment life and void manufacturer warranties. When the cost difference between OEM and generic is $10-30, the OEM part is always the smarter investment on a system worth $5,000-$15,000.

Shipping & Returns

Same-day shipping on orders before 3 PM CST. Standard delivery 2-5 business days, express options available at checkout. 30-day hassle-free returns on uninstalled parts — free return shipping included. 1-year OEM factory warranty coverage.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier PH4ANG042000BCAA?
Yes. This is the factory-specified OEM contactor for the Carrier PH4ANG042000BCAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier PH4ANG042000BCAA?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online