Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Contactor for PH4ANG030000BCAA Heat Pump Package Unit
Carrier

OEM Carrier Contactor for PH4ANG030000BCAA Heat Pump Package Unit

SKU: CARRIE-PH4ANG030000BCAA-CONTACTOR-HN51KC024 Brand: Carrier
Guaranteed to fit — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Contactor for PH4ANG030000BCAA Heat Pump Package Unit

The contactor is the high-current relay that powers the compressor and condenser fan motor in your Carrier PH4ANG030000BCAA heat pump package unit. On every call for heating or cooling, the control board sends 24V to the contactor coil, pulling its contacts together to feed 240V into the outdoor section. Worn or failed contacts produce unmistakable symptoms: the outdoor unit sits dead while the indoor blower runs, a loud humming or chattering rattles from the outdoor cabinet as the contacts arc, or the contacts weld closed and the compressor never shuts off — freezing the evaporator coil and tripping breakers. This is a 2-pole contactor with a 24VAC coil and silver-alloy contacts rated for the unit's full-load and locked-rotor amperage. Before installing, verify the coil voltage (24V), pole count, and contact amp rating match the part you are removing. Genuine OEM is the smart choice for this component. Carrier contactors use silver-cadmium contacts engineered for the compressor's high startup inrush, while generic versions often rely on undersized or copper contacts that pit and erode rapidly. That early wear causes arcing, heat, and voltage drop that strains the compressor windings — turning an inexpensive repair into a far costlier compressor failure. Installation difficulty: 2 out of 5. Tools needed: 1/4" and 5/16" nut drivers, needle-nose pliers, a multimeter, and a photo of the wiring before removal. #1 safety warning: switch off the breaker and the outdoor disconnect, then confirm 0 volts at the line terminals with your meter before touching the contactor — the line side stays energized at 240V regardless of thermostat position. Ships same business day from our stocked warehouse on orders placed before 3 PM CST. Backed by a 1-year OEM warranty and 30-day hassle-free returns on uninstalled parts.

Compatibility

This part is compatible with Carrier model PH4ANG030000BCAA. Always verify the part number against your unit's data plate before ordering.

Why Choose OEM?

OEM parts are manufactured to the exact factory specifications for your unit. Generic aftermarket alternatives may fit physically but often use lower-rated components that reduce equipment life and void manufacturer warranties. When the cost difference between OEM and generic is $10-30, the OEM part is always the smarter investment on a system worth $5,000-$15,000.

Shipping & Returns

Same-day shipping on orders before 3 PM CST. Standard delivery 2-5 business days, express options available at checkout. 30-day hassle-free returns on uninstalled parts — free return shipping included. 1-year OEM factory warranty coverage.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier PH4ANG030000BCAA Heat Pump Package Unit?
Yes. This is the factory-specified OEM contactor for the Carrier PH4ANG030000BCAA Heat Pump Package Unit. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier PH4ANG030000BCAA Heat Pump Package Unit?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.