Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Definite Purpose Contactor Replacement for PH3GNAA30000AA
Carrier

OEM Carrier Definite Purpose Contactor Replacement for PH3GNAA30000AA

SKU: CARRIE-PH3GNAA30000AA-CONTACTOR-HN51KC024 Brand: Carrier
Guaranteed to fit PH3GNAA30000AA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Definite Purpose Contactor Replacement for PH3GNAA30000AA

The contactor is the high-voltage relay that switches 240V power to the compressor and condenser fan motor on your PH3GNAA30000AA. Each time the thermostat calls for heating or cooling, the 24V coil snaps the contacts closed to energize the unit. Because those contacts arc every cycle, they slowly pit and burn — making the contactor the single most common failure on a package unit. Telltale symptoms include short-cycling, a loud hum or buzz from the unit, the compressor and fan failing to start, or contacts that weld shut and leave the unit running nonstop even with the thermostat off. Specifications: This OEM definite-purpose contactor uses a 24V coil and silver-alloy contacts rated for the compressor's full-load and locked-rotor amps. Contact material, gap, and spring tension are matched to Carrier's specification so the contacts break cleanly and resist arcing under inrush. Why OEM matters: Generic contactors often substitute undersized or copper-flashed contacts that pit and carbon up much faster than OEM silver alloy. The rising contact resistance creates heat, drops voltage at the compressor terminals, and cuts compressor life. Cheap aftermarket coils also drop out during brownouts, causing nuisance trips and hard starts. Installation difficulty: 2 of 5. Tools needed: 1/4" and 5/16" nut drivers, a multimeter, and a reference photo of the existing wiring. #1 safety warning: turn off the breaker at the disconnect and confirm 0V with your meter — the line side of the contactor stays energized at 240V even when the system is idle. Ships same business day from our stocked warehouse on orders placed before 3 PM CST. Backed by a 1-year OEM warranty and 30-day hassle-free returns on uninstalled parts.

Compatibility

This part is compatible with Carrier model PH3GNAA30000AA. Always verify the part number against your unit's data plate before ordering.

Why Choose OEM?

OEM parts are manufactured to the exact factory specifications for your unit. Generic aftermarket alternatives may fit physically but often use lower-rated components that reduce equipment life and void manufacturer warranties. When the cost difference between OEM and generic is $10-30, the OEM part is always the smarter investment on a system worth $5,000-$15,000.

Shipping & Returns

Same-day shipping on orders before 3 PM CST. Standard delivery 2-5 business days, express options available at checkout. 30-day hassle-free returns on uninstalled parts — free return shipping included. 1-year OEM factory warranty coverage.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier PH3GNAA30000AA?
Yes. This is the factory-specified OEM contactor for the Carrier PH3GNAA30000AA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier PH3GNAA30000AA?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online