Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Contactor 2-Pole 24V 40A for PH3ANA060000BAAA
Carrier

OEM Carrier Contactor 2-Pole 24V 40A for PH3ANA060000BAAA

SKU: CARRIE-PH3ANA060000BAAA-CONTACTOR-HN52PD024 Brand: Carrier
Guaranteed to fit PH3ANA060000BAAA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier 2-Pole Contactor 24V 40A — HN52PD024 for Model PH3ANA060000BAAA

This OEM Carrier contactor (part #HN52PD024) is the factory-specified high-voltage relay for the Carrier PH3ANA060000BAAA packaged unit. The contactor is the critical electromechanical switch that receives a 24V signal from the thermostat and closes to send line voltage to the compressor and condenser fan motor. When contactors fail — through pitted contacts, a burned coil, or a mechanically stuck plunger — the most common symptom is an air conditioner that simply won't turn on, even when the thermostat is calling for cooling. Secondary symptoms include visible arcing, chattering, or a unit that runs continuously and won't shut off.

  • Specs: 2-Pole | 24V coil voltage | 40A rated | Direct OEM replacement for Carrier part #HN52PD024
  • OEM vs Generic: This is a genuine Carrier OEM contactor built to factory contact gap tolerances and coil pull-in specs. Generic contactors vary widely in contact material quality and coil sensitivity, leading to premature pitting and nuisance dropouts under load.
  • Install difficulty: 3/5 — Line voltage is present inside the unit. Always disconnect power at the disconnect box and verify zero voltage with a multimeter before beginning. Tools needed: flathead and Phillips screwdrivers, 1/4" nut driver, needle-nose pliers, multimeter. Photograph all wire connections before removal.
  • Warranty: 1-year OEM factory warranty against defects. Ships same business day from our warehouse when ordered before cutoff.

Compatibility: Designed as a direct-fit replacement for Carrier model PH3ANA060000BAAA. Verify pole count, coil voltage, and amperage rating against your unit's data plate before ordering. Our technical team is available to confirm fitment — order with confidence and get back up and running today.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier PH3ANA060000BAAA?
Yes. This is the factory-specified OEM contactor for the Carrier PH3ANA060000BAAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier PH3ANA060000BAAA?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online