OEM Carrier High Pressure Switch 395/295 PSI — PH2PNB024000AC
Carrier

OEM Carrier High Pressure Switch 395/295 PSI — PH2PNB024000AC

SKU: CARRIE-PH2PNB024000AC-PRESSURE_SWITCH-HK02ZA395 Brand: Carrier
Guaranteed to fit PH2PNB024000AC — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier High Pressure Switch 395/295 PSI for Model PH2PNB024000AC (HK02ZA395 / HK02ZB044)

This OEM Carrier high pressure switch is the factory-specified refrigerant safety control for the Carrier PH2PNB024000AC heat pump. Manufactured by Sensata on the PS80 platform and certified to CE/EN60730-2-6 standards, it continuously monitors the high-side refrigerant pressure in your system. When pressure exceeds the factory cutout threshold, the switch opens to protect the compressor from catastrophic over-pressure damage. Common failure symptoms include nuisance high-pressure lockouts, the outdoor unit shutting off on warm days, or the system failing to restart after a fault code is cleared — all pointing to a faulty or out-of-spec pressurestat.

  • Specs: Opens at 395 PSI | Closes at 295 PSI | 6(6)A @ 240 VAC | PMAX 41B | 1/8" NPT male thread | Sensata PS80-03-0018 platform | OEM part numbers: HK02ZA395 & HK02ZB044
  • OEM vs Generic: This is a genuine Carrier Factory Authorized Part — not an aftermarket clone. OEM pressurestat calibration is held to tight tolerances; generic copies can drift in cutout pressure, causing premature trips or, worse, failing to protect the compressor when pressure actually exceeds safe limits.
  • Install difficulty: 2/5 — Recover refrigerant before disconnecting the existing switch (required by EPA 608). Tools needed: refrigerant recovery machine, manifold gauges, adjustable wrench, Teflon tape for NPT threads, multimeter to confirm continuity. Always verify the system holds pressure after reinstallation before recharging.
  • Warranty & Shipping: 1-year OEM factory warranty against defects. Ships same business day from our warehouse when ordered before 3 PM local time. Free shipping on orders over $99.

Compatibility: Engineered as a direct OEM replacement for Carrier model PH2PNB024000AC. Also replaces legacy Carrier part numbers 312926-217, 71267D1, HK02ZA380, HK02ZA396, HK02ZA400, HK02ZA401, HK02ZA435, HK02ZA500, and HK02ZA501. Verify your unit's data plate and existing switch PSI rating before ordering. Our fitment team is available to confirm compatibility before you buy.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier OEM Carrier High Pressure Switch 395/295 PSI — PH2PNB024000AC?
Yes. This is the factory-specified OEM pressure switch for the Carrier OEM Carrier High Pressure Switch 395/295 PSI — PH2PNB024000AC. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier OEM Carrier High Pressure Switch 395/295 PSI — PH2PNB024000AC?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.