Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier High & Low Pressure Switch Kit for PH2PNB024000AB
Carrier

OEM Carrier High & Low Pressure Switch Kit for PH2PNB024000AB

SKU: CARRIE-PH2PNB024000AB-PRESSURE_SWITCH-HK02ZA395 Brand: Carrier
Guaranteed to fit PH2PNB024000AB — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier High & Low Pressure Switch Kit — HK02ZA395 + HK02ZB044 — for Model PH2PNB024000AB

This OEM pressure switch kit includes both the high pressure switch (HK02ZA395) and the low pressure switch (HK02ZB044) — the exact factory-specified pair for the Carrier PH2PNB024000AB heat pump. These switches act as safety sentinels in the refrigerant circuit: the high-side switch opens at 395 PSI and resets at 295 PSI, while the low-side switch opens at 7 PSI and closes at 22 PSI with a 50-inch lead. When either switch fails or trips, the system will lock out on a fault code, short-cycle, or refuse to start entirely — symptoms often misdiagnosed as compressor or control board failure.

  • Specs — HK02ZA395 (High Pressure): Open @ 395 PSI | Close @ 295 PSI | 1/8" NPT thread | 240 VAC | PMAX 41B | Replaces: 312926-217, HK02ZA380, HK02ZA396, HK02ZA400, HK02ZA401, HK02ZA435, HK02ZA500, HK02ZA501
  • Specs — HK02ZB044 (Low Pressure): Open @ 7 PSI | Close @ 22 PSI | 50" lead | 24V | Country of Origin: Mexico | Genuine OEM Carrier/Bryant/Payne part
  • OEM vs Generic: OEM pressure switches are factory-calibrated to exact cut-in and cut-out tolerances. Aftermarket substitutes frequently drift out of spec, causing nuisance trips or — more dangerously — failing to protect the compressor from refrigerant overcharge or loss-of-charge events.
  • Install difficulty: 2/5 — Recover refrigerant per EPA 608 before replacing the high-side switch. Tools: manifold gauge set, 1/8" NPT fittings, spanner wrench, multimeter to verify continuity post-install. Always confirm system pressures are within normal operating range before closing up. Low-side switch is a straightforward swap with no refrigerant recovery required on most configurations.
  • Warranty: 1-year OEM factory warranty. Ships same business day from our warehouse when ordered by 3PM local time.

Compatibility: Engineered as a direct OEM replacement for the Carrier PH2PNB024000AB heat pump. Verify model data plate and existing switch PSI ratings before ordering. Not sure? Our fitment team confirms compatibility before you buy — reach out via chat or phone.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier PH2PNB024000AB?
Yes. This is the factory-specified OEM pressure switch for the Carrier PH2PNB024000AB. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier PH2PNB024000AB?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.