Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier High & Low Pressure Switch Kit HK02ZA395 HK02ZB044 — PH1ZP
Carrier

OEM Carrier High & Low Pressure Switch Kit HK02ZA395 HK02ZB044 — PH1ZP

SKU: CARRIE-PH1ZPA048000ABAA-PRESSURE_SWITCH-HK02ZA395 Brand: Carrier
Guaranteed to fit — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier High & Low Pressure Switch Kit HK02ZA395 / HK02ZB044 for Model PH1ZPA048000ABAA

This factory-matched OEM pressure switch set is the direct replacement for the Carrier PH1ZPA048000ABAA heat pump system. The kit includes two critical safety switches that work in tandem to protect the refrigerant circuit: the HK02ZA395 high pressure switch (opens at 395 PSI / closes at 295 PSI) and the HK02ZB044 low pressure switch (opens at 7 PSI / closes at 22 PSI, 50" leads, 24V). When either switch fails, the system will typically lock out, short-cycle, or fail to cool entirely — symptoms often misdiagnosed as compressor or refrigerant issues.

  • Specs — HK02ZA395 High Pressure Switch: Opens 395 PSI | Closes 295 PSI | 1/8" NPT thread | 240 VAC | Sensata PS80 platform | Replaces 312926-217, 71267D1, HK02ZA380, HK02ZA396, HK02ZA400, and more
  • Specs — HK02ZB044 Low Pressure Switch: Opens 7 PSI | Closes 22 PSI | 50" leads | 24V | OEM Carrier RCD | Country of Origin: Mexico
  • OEM vs Generic: OEM switches are calibrated to exact factory cut-in/cut-out setpoints. Aftermarket substitutes frequently drift outside tolerance, triggering nuisance lockouts or — worse — failing to protect the compressor from dangerous pressure extremes.
  • Install difficulty: 3/5 — Refrigerant system must be safely recovered before replacing the high pressure switch. Low pressure switch replacement is less invasive but requires careful lead routing. Tools needed: manifold gauge set, 1" open-end wrench, Schrader valve core tool, thread sealant tape. Always verify system pressures with gauges after replacement.
  • Warranty: 1-year OEM factory warranty on both switches. Orders ship same business day from our warehouse.

Compatibility: Engineered specifically for the Carrier PH1ZPA048000ABAA packaged heat pump unit. Verify refrigerant type and system operating pressures against your unit's data plate before ordering. Our technical team is available to confirm fitment — contact us before you buy if you have any questions.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier OEM Carrier High & Low Pressure Switch Kit HK02ZA395 HK02ZB044 — PH1ZP?
Yes. This is the factory-specified OEM pressure switch for the Carrier OEM Carrier High & Low Pressure Switch Kit HK02ZA395 HK02ZB044 — PH1ZP. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier OEM Carrier High & Low Pressure Switch Kit HK02ZA395 HK02ZB044 — PH1ZP?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online