Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier High Pressure Switch HK02ZA395 for PH1ZNA060000AAAA
Carrier

OEM Carrier High Pressure Switch HK02ZA395 for PH1ZNA060000AAAA

SKU: CARRIE-PH1ZNA060000AAAA-PRESSURE_SWITCH-HK02ZA395 Brand: Carrier
Guaranteed to fit PH1ZNA060000AAAA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier High Pressure Switch HK02ZA395 / HK02ZB044 for Model PH1ZNA060000AAAA

This genuine OEM Carrier high pressure switch (part numbers HK02ZA395 and HK02ZB044) is the factory-specified refrigerant safety switch for the Carrier PH1ZNA060000AAAA packaged heat pump unit. Mounted in the high-side refrigerant circuit, this pressure switch continuously monitors system pressure and opens the circuit when pressure exceeds the safe threshold — protecting the compressor from catastrophic damage. When this switch fails or trips repeatedly, you'll experience nuisance lockouts, no-cooling conditions, or a system that immediately shuts down after startup without an obvious refrigerant-side cause.

  • Specs: Opens at 395 PSI | Closes at 295 PSI | Sensata PS80 series | 6(6)A @ 240 VAC | PMAX 41B | 1/8" NPT male thread connection | SPST normally closed
  • OEM vs Generic: This OEM switch is manufactured to Carrier's exact pressure setpoints (±3% tolerance). Aftermarket alternatives often carry wider tolerances, risking either premature nuisance trips or — more dangerously — failure to open at true overpressure conditions, exposing your compressor to damage.
  • Install difficulty: 2/5 — Refrigerant circuit work must be performed by an EPA 608-certified technician. Recover refrigerant before removing the switch. Tools needed: refrigerant recovery machine, manifold gauge set, adjustable wrench, 1/8" NPT thread sealant. Always leak-check after reinstallation.
  • Warranty: 1-year OEM factory warranty against manufacturing defects. Ships same business day from our warehouse when ordered before 3 PM EST.

Compatibility: Directly fits Carrier model PH1ZNA060000AAAA packaged heat pump units. Also replaces legacy part numbers 312926-217, 71267D1, HK02ZA380, HK02ZA396, HK02ZA400, HK02ZA401, HK02ZA435, HK02ZA500, and HK02ZA501. Verify refrigerant circuit type and existing switch PSI ratings on your unit's data plate before ordering. Our HVAC parts specialists are available to confirm fitment — contact us before you buy.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier PH1ZNA060000AAAA?
Yes. This is the factory-specified OEM pressure switch for the Carrier PH1ZNA060000AAAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier PH1ZNA060000AAAA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online