Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Pressure Switch 7#OPN 22#CLS for PH1REA036000AAWB
Carrier

OEM Carrier Pressure Switch 7#OPN 22#CLS for PH1REA036000AAWB

SKU: CARRIE-PH1REA036000AAWB-PRESSURE_SWITCH-HK02ZB044 Brand: Carrier
Guaranteed to fit PH1REA036000AAWB — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Pressure Switch HK02ZB044 — 7 PSI Open / 22 PSI Close for Model PH1REA036000AAWB

This OEM pressure switch (part number HK02ZB044) is the factory-specified replacement for the Carrier PH1REA036000AAWB packaged heat pump unit. The pressure switch proves that the inducer motor has established adequate draft before allowing ignition to proceed. When this switch fails or becomes stuck open, the control board interprets a draft fault and locks out the unit — resulting in a no-heat condition, a flashing fault code, or a system that attempts startup and immediately shuts down without firing.

  • Specs: Opens at 7 PSI | Closes at 22 PSI | 50" wire leads | 24V coil circuit | Country of Origin: Mexico | OEM part number HK02ZB044
  • OEM vs Generic: This is a genuine Carrier OEM pressure switch engineered to exact factory tolerances. Generic switches can carry wider pressure tolerances, leading to nuisance lockouts or — worse — unsafe operation. OEM ensures the correct trip point every time.
  • Install difficulty: 2/5 — Turn off power at the disconnect before servicing. Tools needed: 1/4" nut driver, flat-head screwdriver, manometer (recommended to verify W.C. at port). Photograph all wiring and tubing routing before disconnecting. Swap hose and connector, restore power, and verify draft-proven status on the board.
  • Warranty: 1-year OEM factory warranty. Ships same business day from our warehouse when ordered before 3 PM local time.

Compatibility: Direct OEM replacement for Carrier model PH1REA036000AAWB packaged heat pump unit. Verify pressure ratings (7 PSI open / 22 PSI close) and lead length (50") against your unit's data plate before ordering. Not sure it fits? Our HVAC parts specialists verify fitment before you buy — reach out via chat or phone before placing your order.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier PH1REA036000AAWB?
Yes. This is the factory-specified OEM pressure switch for the Carrier PH1REA036000AAWB. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier PH1REA036000AAWB?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online