Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Single Run Capacitor Kit 10+15 MFD 370V — PH1PPA048000ACBA
Carrier

OEM Carrier Single Run Capacitor Kit 10+15 MFD 370V — PH1PPA048000ACBA

SKU: CARRIE-PH1PPA048000ACBA-CAPACITOR-P291-1003 Brand: Carrier
Guaranteed to fit PH1PPA048000ACBA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Single Run Capacitor Kit 10 MFD + 15 MFD 370V for Model PH1PPA048000ACBA

This OEM-matched run capacitor kit contains both factory-specified single run capacitors for the Carrier PH1PPA048000ACBA 4-ton packaged heat pump system. Part numbers P291-1003 (10 MFD — condenser fan motor) and P291-1503 (15 MFD — compressor) are the Totaline/Carrier Replacement Components Division capacitors originally installed at the factory. When either capacitor fails, you'll experience symptoms including a loud hum at startup with no motor movement, the system short-cycling within the first few minutes of operation, intermittent cooling or heating failure, or a tripped breaker caused by locked-rotor amperage draw. Replacing both at the same time is strongly recommended — if one has failed, the other is typically at the same age and stress level.

  • Specs — P291-1003 (Fan Motor Cap): 10 MFD (microfarad) | 370 VAC | Oval case | ±6% tolerance | 10,000 AFC protected | Non-PCB dielectric fluid | Operating range: -40°C to +70°C | 50/60 Hz
  • Specs — P291-1503 (Compressor Cap): 15 MFD (microfarad) | 370 VAC | Oval case | ±6% tolerance | 10,000 AFC protected | Non-PCB dielectric fluid | UL-approved current interrupter | 50/60 Hz
  • OEM vs Generic: These are Carrier Totaline Replacement Components Division capacitors — the same specification used on the factory line. Generic capacitors typically carry a ±10% MFD tolerance, which accelerates motor winding wear and reduces compressor service life. OEM-spec ±6% tolerance means tighter start and run performance across the full temperature range.
  • Install difficulty: 2/5 — Turn off power at the disconnect and wait a minimum of 5 minutes before touching any capacitor terminals (capacitors store lethal voltage even when power is off). Discharge with an insulated resistor before removal. Tools required: 1/4" nut driver, needle-nose pliers, multimeter (to verify residual charge and post-install MFD reading). Always photograph all wiring connections before disconnecting. Replace one capacitor at a time to avoid miswiring.
  • Warranty: 1-year OEM factory warranty on both capacitors. Ships same business day from our climate-controlled warehouse.

Compatibility: Engineered as a direct OEM replacement kit for the Carrier PH1PPA048000ACBA 4-ton packaged heat pump. Verify MFD rating and voltage on your unit's data plate before ordering — do not substitute a higher or lower MFD value. Note that P291-1003 has been superseded by P291-1004 (440V-rated) and P291-1503 by P291-1504; both superseding parts are forward-compatible and may ship depending on current factory stock. Questions about fitment? Our HVAC parts team verifies compatibility before every order — contact us before purchasing.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Capacitor fit my Carrier OEM Carrier Single Run Capacitor Kit 10+15 MFD 370V — PH1PPA048000ACBA?
Yes. This is the factory-specified OEM capacitor for the Carrier OEM Carrier Single Run Capacitor Kit 10+15 MFD 370V — PH1PPA048000ACBA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the capacitor on my Carrier OEM Carrier Single Run Capacitor Kit 10+15 MFD 370V — PH1PPA048000ACBA?
Difficulty: Easy (20–30 min)
Step 1: Turn off power at breaker. Step 2: Open condensing unit panel. Step 3: Photograph the old capacitor wiring (Common/Herm/Fan). Step 4: Discharge old capacitor with insulated screwdriver. Step 5: Disconnect and remove old capacitor. Step 6: Mount new capacitor, reconnect wires to matching terminals. Step 7: Close panel, restore power, test. Tools: screwdriver, needle-nose pliers.
My AC hums but won’t start. What part do I need?
An AC that hums but won’t start is the classic symptom of a failed capacitor. The capacitor provides the electrical boost to start the compressor. When it fails, you hear humming but the motor can’t overcome inertia. Other symptoms: fan spinning slowly, AC cycling on/off rapidly, or a visibly swollen capacitor. Fix: replace capacitor ($15–$80 DIY, 30 min).
Is this capacitor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier capacitor?
OEM strongly recommended. OEM capacitors have ±6% MFD tolerance vs aftermarket ±10%. The looser tolerance causes motor winding stress, higher temps, and shorter compressor life. Price difference is only $10–$20 — OEM is the clear value choice.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.