Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier High Pressure Switch 395/295 PSI for PH1PNB018000AAAA
Carrier

OEM Carrier High Pressure Switch 395/295 PSI for PH1PNB018000AAAA

SKU: CARRIE-PH1PNB018000AAAA-PRESSURE_SWITCH-HK02ZA395 Brand: Carrier
Guaranteed to fit PH1PNB018000AAAA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier High Pressure Switch 395/295 PSI for Model PH1PNB018000AAAA

This OEM high pressure switch (part numbers HK02ZA395 and HK02ZB044) is the factory-specified refrigerant-side safety control for the Carrier PH1PNB018000AAAA packaged heat pump unit. Mounted on the high-side refrigerant circuit, this switch continuously monitors discharge pressure and cuts power to the compressor the moment pressure exceeds the factory set point — protecting the compressor from catastrophic over-pressure failure. When this switch fails or drifts out of calibration, you'll typically experience nuisance high-pressure lockouts, a compressor that won't start, or a system that trips on a fault code with no obvious refrigerant cause.

  • Specs: Opens at 395 PSI | Closes at 295 PSI | 1/8" NPT thread connection | 240 VAC rated (6A) | Sensata PS80-03-0018 platform | SPST normally closed | Compatible part cross-reference: 312926-217, 71267D1, HK02ZA380, HK02ZA396
  • OEM vs Generic: OEM Carrier switches (manufactured by Sensata) are calibrated to ±2% of the rated cut-out pressure. Generic aftermarket switches often drift ±8–12%, risking either compressor damage from under-protection or chronic nuisance lockouts from over-sensitivity.
  • Install difficulty: 3/5 — Refrigerant-side work. System must be recovered before replacing this switch if it is installed in a sealed circuit. Tools required: refrigerant recovery machine, manifold gauge set, 1/8" NPT fittings, Schrader valve core tool, and torque wrench. Always verify system pressures after reinstallation before returning to service.
  • Warranty: 1-year OEM factory warranty against defects in materials and workmanship. Ships same business day from our warehouse when ordered before 3 PM local time.

Compatibility: Engineered as a direct OEM replacement for Carrier model PH1PNB018000AAAA. Cross-references OEM part numbers HK02ZA395 and HK02ZB044. Always verify the cut-out and cut-in pressure ratings on your unit's data plate or wiring diagram before ordering — using an incorrect pressure rating can void your equipment warranty. Not sure it fits? Contact our team for fitment verification before you buy.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier PH1PNB018000AAAA?
Yes. This is the factory-specified OEM pressure switch for the Carrier PH1PNB018000AAAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier PH1PNB018000AAAA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online