Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Contactor 1-Pole 24V 25A for PH1PNA030000ABBA
Carrier

OEM Carrier Contactor 1-Pole 24V 25A for PH1PNA030000ABBA

SKU: CARRIE-PH1PNA030000ABBA-CONTACTOR-HN51KB024 Brand: Carrier
Guaranteed to fit PH1PNA030000ABBA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier 1-Pole Contactor 24V 25A — HN51KB024 for Model PH1PNA030000ABBA

This is the genuine OEM replacement contactor for the Carrier PH1PNA030000ABBA heat pump system. The contactor is the high-voltage switching relay that receives a 24V signal from the thermostat or control board and closes the high-voltage circuit to power the compressor and condenser fan motor. When a contactor fails, the result is typically a system that won't energize at all — the thermostat calls for cooling or heating but nothing happens at the outdoor unit, or the unit may short-cycle or hum without starting.

  • Specs: 1-Pole configuration | 24V 50/60Hz coil | 25 FLA (Full Load Amps) | 30 RES rated | OEM part number HN51KB024 — factory-matched for Carrier PH1PNA030000ABBA
  • OEM vs Generic: This is a genuine Carrier OEM contactor built to exact factory specifications. Generic aftermarket contactors often use lighter-gauge contacts that pit and arc faster under load, leading to premature failure and potential compressor damage. OEM ensures the correct coil pull-in voltage and contact rating every time.
  • Install difficulty: 2/5 — Always disconnect power at the disconnect box and wait 5 minutes before servicing. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, multimeter. Photograph all wiring connections before removal. Swap wires one at a time to avoid miswiring.
  • Warranty: 1-year OEM manufacturer warranty. In-stock orders ship same business day from our warehouse.

Compatibility: Designed as the factory-specified contactor for Carrier model PH1PNA030000ABBA. Always verify your existing contactor's pole count, coil voltage, and amp rating against your unit's data plate before ordering. Our HVAC parts specialists are available to confirm fitment — contact us before you buy if you have any questions.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier PH1PNA030000ABBA?
Yes. This is the factory-specified OEM contactor for the Carrier PH1PNA030000ABBA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier PH1PNA030000ABBA?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.