Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Definite Purpose Contactor for Heat Pump PH1PEB060000AAAA
Carrier

OEM Carrier Definite Purpose Contactor for Heat Pump PH1PEB060000AAAA

SKU: CARRIE-PH1PEB060000AAAA-CONTACTOR-HN52KC025 Brand: Carrier
Guaranteed to fit PH1PEB060000AAAA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Definite Purpose Contactor for Heat Pump PH1PEB060000AAAA

The contactor in your Carrier PH1PEB060000AAAA is the electrically controlled switch that closes to deliver high-voltage power to the compressor and outdoor fan motor whenever the thermostat calls for cooling or heating. Because it makes and breaks current under load thousands of times each season, it's one of the most frequent heat pump failure points. Telltale signs include a loud chatter or buzzing at the outdoor unit, a compressor and fan that won't energize, contacts welded shut so the unit runs continuously, and pitted, blackened terminals or a tripped breaker. This is a definite-purpose contactor sized for this chassis: correct pole configuration, a 24V control coil, and silver-alloy contacts rated for the full-load (FLA) and locked-rotor (LRA) amperage this larger compressor and fan motor draw. Proper contact rating is what allows clean, repeated switching without welding. OEM matters because budget aftermarket contactors often use undersized or lower-grade contacts that arc and pit faster, build up resistance, and overheat the connected wiring — accelerating compressor wear and recreating the exact symptoms you're replacing the part to cure. A correctly rated OEM contactor switches reliably for years. Install difficulty: 2 of 5. Tools needed: 1/4" nut driver, insulated flat and Phillips screwdrivers, needle-nose pliers, and a multimeter to test the 24V coil and verify contact continuity. Label every wire before disconnecting. #1 safety warning: turn off the outdoor disconnect AND the main breaker before touching the contactor — the line-voltage terminals remain energized even when the thermostat is off. Ships same business day from our stocked warehouse on orders placed before 3 PM CST. Backed by a 1-year OEM warranty and 30-day hassle-free returns on uninstalled parts.

Compatibility

This part is compatible with Carrier model PH1PEB060000AAAA. Always verify the part number against your unit's data plate before ordering.

Why Choose OEM?

OEM parts are manufactured to the exact factory specifications for your unit. Generic aftermarket alternatives may fit physically but often use lower-rated components that reduce equipment life and void manufacturer warranties. When the cost difference between OEM and generic is $10-30, the OEM part is always the smarter investment on a system worth $5,000-$15,000.

Shipping & Returns

Same-day shipping on orders before 3 PM CST. Standard delivery 2-5 business days, express options available at checkout. 30-day hassle-free returns on uninstalled parts — free return shipping included. 1-year OEM factory warranty coverage.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier Heat Pump PH1PEB060000AAAA?
Yes. This is the factory-specified OEM contactor for the Carrier Heat Pump PH1PEB060000AAAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier Heat Pump PH1PEB060000AAAA?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online