Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier High Pressure Switch HK02ZA395 for PH1PEB036000AAAA
Carrier

OEM Carrier High Pressure Switch HK02ZA395 for PH1PEB036000AAAA

SKU: CARRIE-PH1PEB036000AAAA-PRESSURE_SWITCH-HK02ZA395 Brand: Carrier
Guaranteed to fit PH1PEB036000AAAA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier High Pressure Switch HK02ZA395 / HK02ZB044 for Model PH1PEB036000AAAA

This genuine OEM Carrier high pressure safety switch is the factory-specified replacement for the Carrier PH1PEB036000AAAA heat pump system. The high pressure switch (HK02ZA395) monitors refrigerant pressure on the high side of the refrigerant circuit and acts as a critical safety device — cutting power to the compressor if system pressure exceeds safe operating limits. When it fails or sticks open, the result is a nuisance lockout, a system that won't cool or heat, or a compressor that trips on first start. The companion low pressure switch HK02ZB044 (opens at 7 PSI, closes at 22 PSI) is also listed here and protects against low-side refrigerant loss events such as leaks or severe undercharge.

  • Primary Part (High Pressure): HK02ZA395 | Opens at 395 PSI | Closes at 295 PSI | 240 VAC rated | 1/8" NPT thread | Sensata PS80-03-0018 | Factory tolerance matched for R-410A systems
  • Secondary Part (Low Pressure): HK02ZB044 | Opens at 7 PSI | Closes at 22 PSI | 24V | 50" lead length | Direct OEM drop-in replacement
  • OEM vs Generic: OEM pressure switches are calibrated to exact factory cut-in/cut-out set points. Aftermarket switches frequently deviate from set-point specs, risking either nuisance lockouts or — more critically — failure to protect the compressor at high pressure extremes, leading to catastrophic compressor failure.
  • Install difficulty: 3/5 — Requires EPA 608 certification to work on the refrigerant circuit. Always recover refrigerant before replacing the high-pressure switch if it is wet-side mounted. Tools needed: manifold gauge set, refrigerant recovery unit, adjustable wrench, thread sealant. Verify the system is de-energized before disconnecting any wiring. Photograph all wiring and tubing connections before removal.
  • Warranty: 1-year OEM factory warranty on both HK02ZA395 and HK02ZB044. Ships same business day from our warehouse when ordered by 3 PM local time.

Compatibility: Designed for the Carrier PH1PEB036000AAAA packaged heat pump unit. Cross-references for HK02ZA395 include: 312926-217, 71267D1, HK02ZA380, HK02ZA396, 19240027, HK02ZA400, 312926-225, 312926-226, HK02ZA401, HK02ZA435, HK02ZA500, HK02ZA501. Always confirm refrigerant type and system operating pressures against your unit's data plate before ordering. Our HVAC parts specialists are available to verify fitment — contact us before you order if you have any questions.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier PH1PEB036000AAAA?
Yes. This is the factory-specified OEM pressure switch for the Carrier PH1PEB036000AAAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier PH1PEB036000AAAA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.