OEM Carrier Low Pressure Switch 55-23# — PH16NC06000GBAAA
OEM Carrier Low Pressure Switch 55-23# — PH16NC06000GBAAA
OEM Carrier Low Pressure Switch 55-23# — PH16NC06000GBAAA
OEM Carrier Low Pressure Switch 55-23# — PH16NC06000GBAAA
Carrier

OEM Carrier Low Pressure Switch 55-23# — PH16NC06000GBAAA

SKU: CARRIE-PH16NC06000GBAAA-PRESSURE_SWITCH-312926-258 Brand: Carrier
Guaranteed to fit PH16NC06000GBAAA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Low Pressure Switch 55-23# (312926-258) for Model PH16NC06000GBAAA

This OEM low pressure switch (part number 312926-258) is the factory-specified replacement for the Carrier PH16NC06000GBAAA heat pump. The low pressure switch continuously monitors refrigerant pressure on the suction side of the system. When refrigerant pressure drops below the factory-set threshold — due to a leak, blocked filter, or low charge — the switch opens and shuts down the compressor to prevent catastrophic damage. Common failure symptoms include the system locking out on a low-pressure fault, the compressor cycling off shortly after startup, or the unit running but delivering no cooling or heating.

  • Specs: 55-23# pressure rating | Cut-out: 55 PSIG | Cut-in: 23 PSIG | OEM Sensata / Factory Authorized Parts designation | Pre-wired leads for direct plug-in installation
  • OEM vs Generic: This is a genuine Carrier OEM part (312926-258), precision-calibrated to factory cut-in/cut-out tolerances. Generic pressure switches often use looser set-point tolerances that can allow the compressor to run under unsafe low-charge conditions, risking compressor burnout.
  • Install difficulty: 2/5 — Recover refrigerant charge before disconnecting the switch from the liquid or suction line. Tools needed: refrigerant recovery unit, manifold gauges, wire connectors, multimeter. Always verify system charge after reinstallation and confirm switch continuity before startup.
  • Warranty: 1-year OEM factory warranty against defects. Ships same business day from our warehouse when ordered before 3PM local time.

Compatibility: Direct OEM replacement for Carrier model PH16NC06000GBAAA heat pumps. Always verify the 55-23# pressure rating against your unit's data plate and wiring diagram before ordering. Not sure it fits? Our HVAC parts specialists verify fitment before you buy — no guesswork, no hassle.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier OEM Carrier Low Pressure Switch 55-23# — PH16NC06000GBAAA?
Yes. This is the factory-specified OEM pressure switch for the Carrier OEM Carrier Low Pressure Switch 55-23# — PH16NC06000GBAAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier OEM Carrier Low Pressure Switch 55-23# — PH16NC06000GBAAA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.