Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Replacement Heat Pump Contactor for PH16NC03600GBAAA
Carrier

OEM Carrier Replacement Heat Pump Contactor for PH16NC03600GBAAA

SKU: CARRIE-PH16NC03600GBAAA-CONTACTOR-HN51KC024 Brand: Carrier
Guaranteed to fit PH16NC03600GBAAA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Replacement Heat Pump Contactor for PH16NC03600GBAAA

The contactor is the high-voltage relay that switches line power to the compressor and outdoor fan motor in your Carrier PH16NC03600GBAAA heat pump. When the thermostat calls for cooling or heating, the 24V coil pulls the contacts closed and energizes the unit. A failing contactor typically shows up as a humming or buzzing outdoor unit that won't start, a fan that spins while the compressor stays silent, audible chattering or rapid clicking, or an outdoor unit that keeps running after the thermostat is satisfied — a sign of welded contacts. Burned, pitted, or insect-fouled contacts are one of the most common no-cooling service calls in the field. This is a definite-purpose contactor rated for the PH16's compressor locked-rotor and full-load amps, driven by a 24V coil. Pole count and amperage rating match the factory specification for this model. OEM units use silver-alloy contacts and a coil wound to the exact pull-in voltage the equipment expects. Contactors live and die by contact quality. Generic units often use undersized or lower-grade contacts that pit and arc faster, raising resistance, generating heat, and eventually welding closed — leaving the compressor running with no way to shut off. An undersized coil can drop out during voltage sag and chatter the contacts to death. OEM-rated contacts and coil are built to survive the full cycle count this unit was engineered for. Install difficulty: 2/5. Tools needed: 1/4" nut driver, needle-nose pliers, a multimeter, and a phone photo of the wiring before you disconnect anything. #1 SAFETY WARNING: Turn off the outdoor disconnect AND the breaker — line voltage (240V) is present at the contactor lugs and can be lethal even when the thermostat is off. Ships same business day from our stocked warehouse on orders placed before 3 PM CST. Backed by a 1-year OEM warranty and 30-day hassle-free returns on uninstalled parts.

Compatibility

This part is compatible with Carrier model PH16NC03600GBAAA. Always verify the part number against your unit's data plate before ordering.

Why Choose OEM?

OEM parts are manufactured to the exact factory specifications for your unit. Generic aftermarket alternatives may fit physically but often use lower-rated components that reduce equipment life and void manufacturer warranties. When the cost difference between OEM and generic is $10-30, the OEM part is always the smarter investment on a system worth $5,000-$15,000.

Shipping & Returns

Same-day shipping on orders before 3 PM CST. Standard delivery 2-5 business days, express options available at checkout. 30-day hassle-free returns on uninstalled parts — free return shipping included. 1-year OEM factory warranty coverage.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier PH16NC03600GBAAA?
Yes. This is the factory-specified OEM contactor for the Carrier PH16NC03600GBAAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier PH16NC03600GBAAA?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online