Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Contactor 2-Pole 24V Coil for PH16NA06000GBBAA
Carrier

OEM Carrier Contactor 2-Pole 24V Coil for PH16NA06000GBBAA

SKU: CARRIE-PH16NA06000GBBAA-CONTACTOR-HN51JD026 Brand: Carrier
Guaranteed to fit PH16NA06000GBBAA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier 2-Pole Contactor HN51JD026 for Model PH16NA06000GBBAA

This is the factory OEM replacement contactor for the Carrier PH16NA06000GBBAA heat pump. The contactor is a high-voltage relay controlled by your 24V thermostat signal — it connects and disconnects line voltage to the compressor and condenser fan motor every time your system cycles. When the contactor fails, the unit may hum without starting, fail to respond to the thermostat, run continuously, or simply not turn on at all. Pitted or burned contacts are the most common cause of no-cool and no-heat calls on residential heat pumps.

  • Specs: 2-pole design | 24V AC coil voltage | Heavy-duty silver-alloy contacts | Direct OEM replacement for part number HN51JD026
  • OEM vs Generic: This OEM contactor is built to Carrier factory specifications, including exact coil pull-in voltage and contact surface area. Generic contactors often use lighter contact materials that pit faster and can cause nuisance lockouts within one to two seasons.
  • Install Difficulty: 3/5 — Always shut off power at both the disconnect and breaker before servicing. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, voltage tester, and a phone or camera to photograph wiring before removal. Transfer one wire at a time to avoid miswiring.
  • Warranty: 1-year OEM factory warranty against defects. Ships same business day from our warehouse when ordered before 3 PM local time.

Compatibility: Verified fit for Carrier model PH16NA06000GBBAA heat pump condensing unit. Always confirm your existing contactor's pole count, coil voltage, and amperage rating against your unit's data plate before ordering. Our HVAC parts specialists are available to confirm fitment — contact us before you buy if you have any questions.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier PH16NA06000GBBAA?
Yes. This is the factory-specified OEM contactor for the Carrier PH16NA06000GBBAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier PH16NA06000GBBAA?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online