OEM Carrier Low Pressure Switch 312926-258 (55-23#) for Model PH16NA04800GACAA

This is the genuine OEM Carrier low pressure switch (part number 312926-258), the factory-specified replacement for the Carrier PH16NA04800GACAA heat pump. The low pressure switch monitors refrigerant pressure on the suction side of the circuit and opens the compressor control circuit any time pressure drops below the factory cutout threshold — protecting the compressor from catastrophic damage caused by low charge, refrigerant loss, or a blocked metering device. Common failure symptoms include nuisance lockouts with a fault code, compressor short-cycling, or a system that trips on a low-pressure fault immediately after startup.

  • Specs: 55-23# pressure rating | Cut-out: 55 PSIG (opens) | Cut-in: 23 PSIG (closes) | Factory Authorized Parts (FAP) designation | Cross-references: Sensata PS80-02-F1270, PSL 312926-258, 300R18
  • OEM vs Generic: This is a genuine Carrier Factory Authorized Part, precision-calibrated at the factory to exact cut-out/cut-in pressures. Aftermarket switches frequently carry ±5–10% pressure tolerances, which can cause nuisance trips or, worse, fail to protect the compressor at the correct threshold.
  • Install difficulty: 2/5 — System must be recovered or isolated before removal. Tools needed: adjustable wrench, refrigerant recovery equipment (EPA 608 required), wire strippers, and a multimeter to verify continuity after installation. Always confirm the system is de-energized before disconnecting leads.
  • Warranty: 1-year OEM manufacturer warranty. In stock and ships same business day from our warehouse.

Compatibility: Designed for the Carrier PH16NA04800GACAA heat pump. Verify your existing switch's pressure ratings (cut-out/cut-in) and connector type against your unit's data plate before ordering. Questions about fitment? Our HVAC parts specialists verify compatibility before you buy — contact us today and get your system back online fast.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier PH16NA04800GACAA?
Yes. This is the factory-specified OEM pressure switch for the Carrier PH16NA04800GACAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier PH16NA04800GACAA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online