Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Low Pressure Switch 55-23# for PH16NA03600GACAA
Carrier

OEM Carrier Low Pressure Switch 55-23# for PH16NA03600GACAA

SKU: CARRIE-PH16NA03600GACAA-PRESSURE_SWITCH-312926-258 Brand: Carrier
Guaranteed to fit PH16NA03600GACAA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Low Pressure Switch 55-23# (312926-258) for Model PH16NA03600GACAA

This is the genuine OEM Carrier Low Pressure Switch (part number 312926-258), factory-specified for the Carrier PH16NA03600GACAA heat pump system. The low pressure switch continuously monitors refrigerant-side pressure and acts as a critical safety device: when refrigerant pressure falls below the factory-set threshold, the switch opens and interrupts operation to prevent compressor damage from low-charge or restricted-flow conditions. A failed low pressure switch typically causes repeated short-cycling, a system lockout fault code, or a unit that starts briefly and shuts down within seconds.

  • Specs: 55-23# Low Pressure Switch | Manufacturer: Carrier (OEM) | Cross-reference: Sensata PS80-02-F1270 | Pre-wired with color-coded leads | Brass inlet connector with precision-calibrated diaphragm
  • OEM vs Generic: This OEM unit is factory-calibrated to exact cut-in/cut-out pressure thresholds for the PH16NA03600GACAA. Aftermarket switches may carry wider pressure tolerances, risking nuisance trips or — worse — failure to protect the compressor under a genuine low-charge condition.
  • Install Difficulty: 2/5 — Always recover refrigerant per EPA Section 608 regulations before opening the refrigerant circuit. Tools needed: manifold gauge set, refrigerant recovery unit, adjustable wrench, multimeter. Photograph all wiring before disconnecting leads. Verify system pressure after reinstallation before restarting.
  • Warranty: 1-year OEM factory warranty. In-stock and ships same business day from our warehouse.

Compatibility: Designed for the Carrier PH16NA03600GACAA heat pump. Always verify your unit's data plate and existing switch markings match the 55-23# specification before ordering. Not sure it fits? Our HVAC parts specialists confirm fitment before you buy — reach out before placing your order.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier PH16NA03600GACAA?
Yes. This is the factory-specified OEM pressure switch for the Carrier PH16NA03600GACAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier PH16NA03600GACAA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.