OEM Carrier 55-23# Low Pressure Switch 312926-258 for Model PH15NB04800GACAA

This is the genuine OEM factory-specified low pressure switch for the Carrier PH15NB04800GACAA heat pump. Part number 312926-258, this 55-23# switch continuously monitors refrigerant pressure on the low side of the refrigerant circuit. When system pressure drops below the threshold — due to a refrigerant leak, blocked filter, or failed metering device — the switch opens and cuts power to the compressor, preventing costly damage from running under inadequate pressure conditions. Common symptoms of a failed low pressure switch include the system not starting, the compressor cycling off immediately after startup, or a fault code indicating a low-pressure lockout.

  • Specs: 55 PSI cut-out / 23 PSI cut-in | Factory-calibrated set points | OEM part number 312926-258 | Also cross-references: Sensata PS80-02-F1270, PSL 312926-258
  • OEM vs Generic: This is a genuine Carrier Factory Authorized Part with precision-calibrated set points matched to the PH15NB04800GACAA's refrigerant circuit design. Aftermarket switches often use wider pressure tolerances, risking nuisance trips or — worse — inadequate compressor protection.
  • Install difficulty: 3/5 — Refrigerant system work requires an EPA 608 certified technician. Tools needed: manifold gauge set, refrigerant recovery equipment, wire crimpers, and a multimeter to verify switch continuity before reinstall. Always recover refrigerant before disconnecting the switch.
  • Warranty: 1-year OEM factory warranty. In stock and ships same business day from our warehouse.

Compatibility: Designed as a direct OEM replacement for Carrier model PH15NB04800GACAA heat pumps. Verify the 55-23# pressure rating against your unit's data plate and wiring diagram before ordering. Our fitment team is available to confirm compatibility — reach out before you order and we'll verify your application.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier PH15NB04800GACAA?
Yes. This is the factory-specified OEM pressure switch for the Carrier PH15NB04800GACAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier PH15NB04800GACAA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.