Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier High & Low Pressure Switch Kit for PH15NB02400GBBAA
Carrier

OEM Carrier High & Low Pressure Switch Kit for PH15NB02400GBBAA

SKU: CARRIE-PH15NB02400GBBAA-PRESSURE_SWITCH-312926-252 Brand: Carrier
Guaranteed to fit PH15NB02400GBBAA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier High & Low Pressure Switch Kit 312926-252 / 312926-258 for Model PH15NB02400GBBAA

These OEM Carrier refrigerant pressure switches are the factory-specified replacements for the Carrier PH15NB02400GBBAA heat pump. The high-pressure switch (312926-252, 670/470 PSI) and low-pressure switch (312926-258) are critical safety controls that continuously monitor refrigerant circuit pressure. When system pressure drifts outside the safe operating band — due to refrigerant loss, a blocked coil, or a failing TXV — these switches cut power to the compressor to prevent catastrophic damage. Typical failure symptoms include nuisance lockouts, fault codes indicating high or low pressure trips, short-cycling, or a compressor that runs briefly and then shuts off entirely.

  • Specs: High-pressure switch 312926-252: 670 PSI cutout / 470 PSI cut-in | Low-pressure switch 312926-258: monitors suction-side pressure | Both rated for R-410A refrigerant systems | SPST normally-closed configuration
  • OEM vs Generic: Genuine Carrier OEM switches are calibrated to exact factory trip points. Aftermarket alternatives frequently drift ±10–15% from rated thresholds, risking compressor damage or nuisance trips that are difficult to diagnose.
  • Install difficulty: 3/5 — Refrigerant circuit must be recovered before replacing switches on a live system. A licensed HVAC/R technician is required for this repair. Tools needed: refrigerant recovery machine, manifold gauge set, adjustable wrench, multimeter. Always de-energize the unit before beginning work.
  • Warranty: 90-day OEM manufacturer warranty. In-stock units ship same business day from our warehouse.

Compatibility: Engineered as direct OEM replacements for the Carrier PH15NB02400GBBAA 2-ton R-410A heat pump. Always confirm refrigerant type and pressure ratings on your unit's data plate before ordering. Not sure if these parts fit your exact serial range? Our team verifies fitment before you order — contact us and we'll confirm in minutes.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier PH15NB02400GBBAA?
Yes. This is the factory-specified OEM pressure switch for the Carrier PH15NB02400GBBAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier PH15NB02400GBBAA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online